background image

 

2

 
 
 
 
 
 
 
 

OPERATION OF DIGI 1 

 
GENERAL: 

 

Backup function

 

The unit has a backup time of approximately 60 minutes. 
In the event of a power outage, the unit will remain operational for 60 minutes. 
If the power outage exceeds 60 minutes, the unit will shut down all currently running functions 
and return to standby mode. 
All programme values and settings are stored in a permanent memory, which is not affected by 
power outages. 

 

Quick functions

 

Factory settings: Run time 2h and temperature 80°C. 

 

Temperature units 

The sauna room temperature can be displayed in either Celsius (°C) or Fahrenheit (°F). 

 

Change of the display units is possible when the unit is in standby mode (display off): 

 

 

-

 

Press and release the Temperature button. The display will indicate the currently selected 
temperature unit (CELC or FAHr) 

-

 

Within 5 seconds press either the Arrow up or Arrow down button to change the displayed 
temperature unit 

-

 

Accept the change by pressing the OK button or by waiting 5 seconds. The unit will return 
to standby mode (display off) 

 

Sauna run time 

The maximum sauna run time is normally 6 h. Jumper on connector J3 disconnected.  
The maximum run time is 12 h, when jumper on connector J3 is installed. 
 
- temperature setting: 0 - 110°C 
- run time: 6h or 12h  
- preset time 0 – 24h 

 

Alarms

 

The unit will indicate when the high temperature limiter is activated. 

 

 

 

 

 

The display will show: 

Err1

 

The alarm is reset by pressing the 

ON_OFF 

button. 

 

Note! 

Before the unit is reset the cause of the overheating must be checked / corrected by a 

qualified person.

 

 

Temp setting

  

Setting 0-110°C. PID control. 
Power outputs are set in ratios of 0/0, 1/3, 2/3 and 3/3, depending on the difference between 

set and measured temperatures. 

 

Display 

The display hours and minutes are divided by a colon. 

 

When showing temperature, the leading zeros are blanked out. 

 

When the timer is running, the colon will blink once every second. 

 

The unit counts down from the set time. 

 

Example: 
The preset time is 

2:00 

h, followed by a reading of 

1:59

,

1:58

, etc. 

The display reading indicates the time remaining until heating starts. 
 
 
 
 
 
 
 

Отзывы: