About this Manual

This manual provides information on how to use i.Series

®

 and Horizon Series

 undercounter laboratory and plasma storage 

freezers. It is intended for use by end users of the freezer and authorized service technicians.
Models are indicated by a distinguishing model number that corresponds to the series, type, number of doors, and capacity of the 
refrigerator. For example, “iLF105” refers to an i.Series Laboratory Freezer with 1 door and a capacity of 5 cu ft, while “HLF104” 
refers to a Horizon Series Laboratory Freezer with 1 door and a capacity of 4 cu ft.
Generic references are used throughout this manual to group models that contain similar features.  For example, “105 models” 
refers to all models of that size (iPF105, HPF105, iLF105, HLF105).  This manual covers all undercounter freezers, which may be 

identified singly, by their size, or by their respective “Series.”

1.1 

Safety Precautions and Symbols

Symbols found in this document

The following symbols are used in this manual to emphasize certain details for the user:

Task

  Indicates procedures which need to be followed.

Note

  Provides useful information regarding a procedure or operating technique when using Helmer 

Scientific products.

NOTICE

  Advises the user against initiating an action or creating a situation which could result in damage to 

equipment; person injury is unlikely.

 

 Symbols found on the units

The following symbols may be found on the freezer or freezer packaging:

Caution: Shock/electrical hazard

Refer to documentation

Caution: Risk of damage to equipment or 
danger to operator

Содержание Horizon HLF104-ADA

Страница 1: ...eration Manual i Series and Horizon Series Undercounter 360376 C Laboratory i Series iLF104 ADA iLF105 Horizon Series HLF104 ADA HLF105 Plasma Storage i Series iPF104 ADA iPF105 Horizon Series HPF104...

Страница 2: ...manual is intended as a guide to provide the operator with necessary instructions on the proper use and maintenance of certain Helmer Scientific products Any failure to follow the instructions as desc...

Страница 3: ...d Disable Active Alarms 12 4 Min Max Temperature Monitoring 13 5 i Series Access Control Optional 14 5 1 Setup 14 5 2 Open Freezer with Access Control 14 6 Horizon Series Operation 15 6 1 Initial Powe...

Страница 4: ...models that contain similar features For example 105 models refers to all models of that size iPF105 HPF105 iLF105 HLF105 This manual covers all undercounter freezers which may be identified singly b...

Страница 5: ...ls Ensure biological materials are stored safely in accordance with all applicable organizational regulatory and legal requirements REQUIRED Decontaminate parts prior to sending for service or repair...

Страница 6: ...eling feet installed Back brace bars and front stabilizing brackets must be installed Blue PN 400821 1 Stainless Steel PN 400821 2 When stacking units place the heavier unit on the bottom Do not open...

Страница 7: ...ximately 4 oz 120 mL of product simulation solution 3 Secure cap on bottle and place in bracket 4 Replace probes immersing at least 2 50 mm in solution 2 6 Chart Recorder if included Note For complete...

Страница 8: ...ine groove 5 Hold chart paper in place while making sure the chart knob is fully tightened Failure to fully tighten the knob can result in paper slipping and losing time 6 Confirm the temperature rang...

Страница 9: ...F switch ON 3 Switch back up battery switch ON Notes For models equipped with optional Access Control the back up battery is turned ON with a key switch The Start screen is displayed when the i C3 is...

Страница 10: ...erature occurs refer to the service manual for troubleshooting 3 2 Operation Notes Refer to the i C3 User Guide for complete information regarding the i C3 User Interface The i C3 Home screen displays...

Страница 11: ...perature setpoints Touch minus or plus on the spin box to change the value Settings screen Device Control Settings screen Notes Default Settings password is 1234 Default setpoint is 30 0 C 3 4 Set Ala...

Страница 12: ...e Failure Control probe not functioning properly Evap Defrost Probe Failure Evaporator defrost probe not functioning properly Compressor High Temperature Compressor temperature reading is above high t...

Страница 13: ...ill active after the mute delay has ended the audible alarm will sound Enter the Settings password Scroll down to select Sound Settings Touch minus or plus on spin box to set the mute duration Table 2...

Страница 14: ...ure reading since the last system reset power on event or manually initiated reset Touch the Reset icon to the right of the display to manually reset Notes The Min Max temperature display can be turne...

Страница 15: ...secure storage for freezer contents Refer to the i C3 User Guide for complete information regarding Access Control 5 1 Setup Configure and manage user specific accounts to allow controlled access to t...

Страница 16: ...ial numbers of 2015494 or higher Some exceptions may exist For confirmation on your unit please contact Helmer Technical Service Units that do not include the minimum and maximum recording feature wil...

Страница 17: ...seconds CLr will be displayed followed by a series of 3 beeps to indicate exit back to the temperature display Notes The minimum and maximum temperature and timer will reset when the unit is powered o...

Страница 18: ...te an acceptable margin of error between the actual temperature value and the desired temperature value Monitor Offset Value is factory set to match a calibrated reference thermometer Refer to the ser...

Страница 19: ...point Power Failure PoFF appears on display Power to unit has been disrupted Probe Failure Prob appears on display Probe not functioning properly Door Open 3 min DOOR ALARM lamp lights Door is open le...

Страница 20: ...ster code also releases the door lock Note The master code should be changed to prevent unauthorized user code setup Enter unique user codes for up to 100 users Each user code is stored with a specifi...

Страница 21: ...values are subject to change Refer to the product specification label on your unit for current values The interface on the remote alarm monitoring system is intended for connection to the end user s...

Страница 22: ...60 Hz 5 75 4 113 Undercounter Single hinged solid 2 24 x 31 5 x 28 5 610 x 801 x 724 217 99 HPF104 ADA 115V 60 Hz 5 75 4 113 Undercounter Single hinged solid 2 24 x 31 5 x 28 5 610 x 801 x 724 211 96...

Страница 23: ...this directive Do not dispose of this product as unsorted municipal waste Collect this product separately Use the collection and return systems available locally For more information on the return rec...

Страница 24: ...E Door handle includes manual keyed lock U Access port F Magnetic lock assembly includes magnet and handle V Drain Line G Back up battery key switch optional Access Control W Compressor H Condenser g...

Страница 25: ...T Drain Line F Door handle includes manual keyed lock U Compressor G Magnetic lock assembly includes magnet and handle V Condensate evaporator H Back up battery key switch optional Access Control W P...

Страница 26: ...Helmer Scientific 14400 Bergen Boulevard Noblesville IN 46060 USA Copyright 2019 Helmer Inc 360376 C...

Отзывы: