Hella PAN 7040 Скачать руководство пользователя страница 12

Installation Instructions and Instructions for Use 

 

 

 

Subject to technical modifications. – Date of Issue 

September/2020 

43 

Awning installation modular 

 

  

 

Tension the cover by slightly retracting the awning. Then slip down and 
remove the arm sleeves from the folding arm towards the middle. 

 

Note!

 

The arm sleeves must not be removed prematurely under any 
circumstances! There is a high risk of accidents and danger to life! 
Check again all installation steps performed. Both the arm bearing and the 
seal profile must be screwed down correctly prior to removing the arm 
sleeves. 

 

Slide the slot nut (2) with the fillister head screws (3) in the depicted 
grooves of the front rail (4). Then attach the end cap (1). Then tighten the 
fillister head screws on the end cap. 

  

 

  

 

  

 

  

Legend 

  End cap 

  Slot nut 

  Cylinder head bolt 

  Front rail 

  

1

2

3

Installation Instructions and Instructions for Use 

 

 

44 

Subject to technical modifications. – Date of Issue 

September/2020 

 

Awning installation modular 

 

  

 

Attach the end cap (1) to the end plate (2). Press until the snap-fit 
assembly snaps into place. The end cap (1) should then be flush with the 
cassette and cover the end plate (2). 

  

 

  

 

  

 

  

Legend 

  End cap 

  End plate 

  

1

2

Installation Instructions and Instructions for Use 

 

 

 

Subject to technical modifications. – Date of Issue 

September/2020 

45 

Awning installation modular 

 

  

 

Finally clip the inspection cover (1) into the statics profile (2) from the 
bottom. 

  

 

  

 
 

  

 

In addition, the inspection cover (1) must be secured on both ends by 
means of the fastening screw (4). 

  

 

  

 
 
 
 

  

Legend 

  Inspection cover 

  Statics profile bottom 

  Detail section view 

  Fastening screw pan-

head tapping screw 
3.9x25 AW20 

  End cap 

  

  

1

2

3

1

4

5

Installation Instructions and Instructions for Use 

 

 

46 

Subject to technical modifications. – Date of Issue 

September/2020 

 

Adjusting the awning 

Inclination adjustment with standard arm bearing 
 

  

To adjust the angle of inclination, the cassette awning PAN 7040 is equipped with an 
adjusting mechanism, which enables an inclination from approx. 5° to 40°. 
The angle of inclination and the horizontal position of the front rail are adjusted by the 
factory.  
If a modification is required, please proceed as described in the following: 

  

 
 

  

 

Completely extend the awning. 

 

Put an Allen key 6 mm (5) onto the adjusting spindle (4). The casing of the 
awning raises or lowers by turning the key (see the figure on the following 
page). 

 

The respective arm can be adjusted easier if a second person slightly lifts 
up the front rail (6). 

 

Proceed analogously with the second adjusting mechanism. The awning 
raises or lowers side by side. 

 

Ensure that the angle of the folding arms to one another is not more than 
5° during the adjustment procedure. Thus the adjustment procedure is to 
be repeated several times on the left and right of the adjustment spindles 
until the desired inclination is reached. 
Never turn against greater resistance. 

 

Check the correct adjustment on the front rail by means of a spirit level in 
the extended condition. 

  

Содержание PAN 7040

Страница 1: ...nstructions we describe the basic installation commissioning and use For authorized specialist staff For the consumer user The following symbols will assist you with the installation or use and requir...

Страница 2: ...s against the danger of squashing especially when operating the unit with automatic devices Place the operating switch within sight of the unit but not near any of the moving parts Never let children...

Страница 3: ...s in the colour Please note that the awning will cause a different colour effect in sunlight and in shade Naturally the optical colour perception depends on the composition and the intensity of the em...

Страница 4: ...ting is switched on or off or dimmed You will find detailed information in the enclosed instructions of the manufacturer Hand held radio transmitter with scroll wheel Setting the scroll wheel function...

Страница 5: ...ns of the anchor manufacturer when tightening the screws Please note that the bore hole geometry is decisive for the load bearing capacity of an anchor All elongated holes defined in the bracket must...

Страница 6: ...September 2020 21 Installation on concrete 60 200 mm ETICS Installation of the anchor rod as per approval ETA 02 0024 Drilled hole preparation 18 mm Observe the anchoring depth and the minimum edge d...

Страница 7: ...er 2020 25 Installation on wood 60 170 mm ETICS Installation of the anchor rods Drilled hole preparation 14 mm Observe the anchoring depth and the minimum edge distance of 100 mm Drilled hole cleaning...

Страница 8: ...ct to technical modifications Date of Issue September 2020 29 Installation on concrete ceiling face installation set 10 Fixing of the bracket Attach the wall bracket type I while doing so push the anc...

Страница 9: ...ions Date of Issue September 2020 Installation of the awning Finally clip the inspection cover 1 into the statics profile 2 from the bottom In addition the inspection cover 1 must be secured on both e...

Страница 10: ...iculated arms are under high mechanical stress With the lower modular group they are secured by means of arm sleeves When removing the sleeves this potential energy discharges There is a danger to lif...

Страница 11: ...e sides on both ends together with the lower part of the static profile 2 Legend Pan head self tapping screw DIN 7981C 3 9x25 AW20 Statics profile bottom Upper modular assembly 1 2 3 Installation Inst...

Страница 12: ...ofile 2 from the bottom In addition the inspection cover 1 must be secured on both ends by means of the fastening screw 4 Legend Inspection cover Statics profile bottom Detail section view Fastening s...

Страница 13: ...pported by hand 8 Check the adjustment of the inclination and if necessary repeat the described procedure until the desired result has been reached Now the adjusting procedure of the arm bearing 3 reg...

Страница 14: ...nge the parts under preload and or the folding arms must all be secured against unintentional extension when dismounting the upper covering profile There is a high risk of accidents 1 Installation Ins...

Страница 15: ...led Both the instructions and notes given in these instructions as well as the instructions and notes given in the respective enclosed instructions of the manufacturers of the drive systems must be ob...

Страница 16: ...perature 2700 K warm white Colour rendering index of the LED strips 90 Control LED Somfy io ONYX dimmable Operating temperature outside temperature 20 C to 45 C IP rating IP44 Cable 10 m with open end...

Страница 17: ...s showing all available devices The overview displays ONYX LED as LED ONYX LED is connected with the hand held radio transmitter via Adaption to the system Then follow the instructions on the screen T...

Страница 18: ...f the device in accordance with the current country specific regulations for electronic scrap e g collecting points Installation Instructions and Instructions for Use Subject to technical modification...

Страница 19: ...3 Installation Instructions and Instructions for Use Subject to technical modifications Date of Issue September 2020 73 Replacing a folding arm with integrated LED lighting Exchange procedure 2 Provi...

Страница 20: ...o technical modifications Date of Issue September 2020 Removal and Disposal With removal or disposing of the awing the parts that are under prestress e g articulated arms counter draw systems must be...

Страница 21: ...serve for the light regulation as view protection anti glare blind and heat protection HELLA Front mounted Roller Shutter for more safety and protection against rain wind heat the cold noise incident...

Отзывы: