Installation Instructions and Instructions for Use
Subject to technical modifications – Date of Issue May/2020
11
Settings
Device type
The different device types can be selected in the ONYX
®
-app under “ad-
vanced settings”.
It is necessary to define the type of device. By selecting the appropriate
category, it is assigned to this type. Device types are outdoor blind, roller
shutter, awning, facade blind and light. For device types, you do not want to
be displayed in the app, i.e. central pushbutton without a connected drive,
the drive type “Hidden” is available. By default the device type “Roller shut-
ter” is set.
Outdoor blind parameters
You find the outdoor blind parameters under “advanced settings” in the ON-
YX
®
-app.
Under “Tilting time” it is possible to transmit the time the outdoor blind re-
quires for a complete tilting to the ONYX
®
control. This must especially be
observed, if a drive with a slow slat tilting is mounted.
Preset tilting times:
Outdoor blind 90°:
1.25 s
Outdoor blind
180°:
2.5 s
Motor parameters
You find the adjustment possibilities for the motors under “advanced set-
tings” in our ONYX
®
-app.
If your sun protection unit moves contrary to the direction of your control
command, you can activate the reversal of the direction of rotation with the
icon “Reverse direction of rotation”.
In addition, the “automatic running time” can be activated/deactivated under
“motor parameters”. The automatic running time should be deactivated only,
if ONYX.NODE is not directly connected to a drive, i.e. to a cut-off relay. The
running time can be adjusted manually, when the automatic running time is
deactivated. As a standard the automatic running time is activated.
Installation Instructions and Instructions for Use
12
Subject to technical modifications – Date of Issue May/2020
Settings
Pushbutton settings
You find the adjustment possibilities for the pushbutton under “advanced
settings” in the ONYX
®
-app.
The actuating direction at the connected Venetian blind pushbutton can be
reversed with “Reverse direction of pushbutton”. This function can be useful,
if the Venetian blind pushbutton is not correctly connected to ONYX.NODE.
Under “Forwarding pushbutton actuation” the pushbutton signal of the con-
nected Venetian blind pushbutton can be forwarded to other ONYX
®
compo-
nents. This function can be used for groups, which can be activated via one
single pushbutton.
Wind resistance class
You find the wind resistance classes in the ONYX
®
-app under “advanced
settings”. These preset wind resistance classes are only relevant, if the op-
tional weather sensor ONYX.WEATHER is used. Please note, that the real
values set depend on the installation situation on-site; these values are
available in the documentation of the sun protection device and must be
strictly observed!
Preset wind resistance classes:
Roller shutter
Class 4 (13.8 m/s)
Awning
Class 2 (10.7 m/s)
Facade blinds
Class 4 (13.8 m/s)
Outdoor blind
Class 4 (13.8 m/s)
Installation Instructions and Instructions for Use
Subject to technical modifications – Date of Issue May/2020
13
Settings
Output selection and entry type
These two adjusting possibilities are only available for the device type “light”.
Under “output selection” you can select the output of the “motor”-terminal to
be used for the actuation of the lighting. It is possible to select between
“Channel A” (connection N and
) and “Channel B” (connection N and
).
As a standard “Channel A” is set.
Under “Entry type” you can select, if a pushbutton or a switch is connected to
the control device.
As a standard “pushbutton” is set.
A detailed description of all settings of the ONYX
®
-app are available in the
download area of our website https://www.hella.info.
Installation Instructions and Instructions for Use
14
Subject to technical modifications – Date of Issue May/2020
Ideal use of the radio signal
In case of bad reception, the position of the ONYX.NODE must be changed.
Radio systems that send on the same frequency may cause interference
with reception.
It must be considered that the range of the radio signal is limited by statutory
regulations and structural measures.