Installation Instructions and Instructions for Use 

 

 

Subject to technical modifications – Date of Issue May/2020 

11

Settings 

 

  

 

Device type 

The different device types can be selected in the ONYX

®

-app under “ad-

vanced settings”. 

 

It is necessary to define the type of device. By selecting the appropriate 
category, it is assigned to this type. Device types are outdoor blind, roller 
shutter, awning, facade blind and light. For device types, you do not want to 
be displayed in the app, i.e. central pushbutton without a connected drive, 
the drive type “Hidden” is available. By default the device type “Roller shut-
ter” is set. 

  

 

  

 

Outdoor blind parameters 

You find the outdoor blind parameters under “advanced settings” in the ON-
YX

®

-app. 

 

Under “Tilting time” it is possible to transmit the time the outdoor blind re-
quires for a complete tilting to the ONYX

®

 control. This must especially be 

observed, if a drive with a slow slat tilting is mounted. 
 

 

Preset tilting times: 

 

Outdoor blind 90°: 

1.25 s 

Outdoor blind 
180°: 

2.5 s 

 

  

 

  

 

Motor parameters 

You find the adjustment possibilities for the motors under “advanced set-
tings” in our ONYX

®

-app. 

 

If your sun protection unit moves contrary to the  direction of your control 
command, you can activate the reversal of the direction of rotation with the 
icon “Reverse direction of rotation”. 

 

In addition, the “automatic running time” can be activated/deactivated under 
“motor parameters”. The automatic running time should be deactivated only, 
if ONYX.NODE is not directly connected to a drive, i.e. to a cut-off relay. The 
running time can be adjusted manually, when the automatic running time is 
deactivated. As a standard the automatic running time is activated. 

  

Installation Instructions and Instructions for Use 

 

12 

Subject to technical modifications – Date of Issue May/2020 

Settings 

 

  

 

Pushbutton settings 

You find the adjustment possibilities for the pushbutton under “advanced 
settings” in the ONYX

®

-app. 

 

The actuating direction at the connected Venetian blind pushbutton can be 
reversed with “Reverse direction of pushbutton”. This function can be useful, 
if the Venetian blind pushbutton is not correctly connected to ONYX.NODE. 

 

Under “Forwarding pushbutton actuation” the pushbutton signal of the con-
nected Venetian blind pushbutton can be forwarded to other ONYX

®

 compo-

nents. This function can be used for groups, which can be activated via one 
single pushbutton. 

  

 

  

 

Wind resistance class 

You find the wind resistance classes in the ONYX

®

-app under “advanced 

settings”. These preset wind resistance classes are only relevant, if the op-
tional weather sensor ONYX.WEATHER is used. Please note, that the real 
values set depend on the installation situation on-site; these values are 
available in the documentation of the sun protection device and must be 
strictly observed! 
 

  

Preset wind resistance classes: 

 

Roller shutter 

Class 4 (13.8 m/s) 

Awning 

Class 2 (10.7 m/s) 

Facade blinds 

Class 4 (13.8 m/s) 

Outdoor blind 

Class 4 (13.8 m/s) 

 

  

Installation Instructions and Instructions for Use 

 

 

Subject to technical modifications – Date of Issue May/2020 

13

Settings 

 

  

 

Output selection and entry type 

These two adjusting possibilities are only available for the device type “light”. 
 
Under “output selection” you can select the output of the “motor”-terminal to 
be used for the actuation of the lighting. It is possible to select between 
“Channel A” (connection N and 

) and “Channel B” (connection N and 

). 

As a standard “Channel A” is set. 
 
 
Under “Entry type” you can select, if a pushbutton or a switch is connected to 
the control device. 
As a standard “pushbutton” is set. 

  

 

  

 

A detailed description of all settings of the ONYX

®

-app are available in the 

download area of our website https://www.hella.info. 

  

Installation Instructions and Instructions for Use 

 

14 

Subject to technical modifications – Date of Issue May/2020 

Ideal use of the radio signal 

 

  

 

In case of bad reception, the position of the ONYX.NODE must be changed. 

  

 

Radio systems that send on the same frequency may cause interference 
with reception. 
It must be considered that the range of the radio signal is limited by statutory 
regulations and structural measures. 

  