31
mega macs 42 Section F 1/2
Diagnosis > Fault code <
If a component malfunction is detected while ECU carries out an internal test, a fault code is set in memory
and the corresponding warning lamp is being activated. Mega macs 42 enables not only single request but
also the overall request of all component modules in a vehicle. The following results are possible:
After finishing the overall request, it is also possible to directly read out the individual components.
Steps:
1. Select the component module.
2. Start the communication with >F1<.
Steps for the individual component retrieval
1. Connect mega macs 42 as described in section E - communication establishment.
> 306 > 306 2.0tD HDi > fault code > engine
amount of faults: 3
fault code: 832
CamsHaft sensor
fault code: 560
primarY eleCtriC CirCUit of fUel pUmp
fault code: 545
aCCelerator sensor 2
f1 system info f3 Delete enter Details
fault 0 communication oK no fault saved
fault xx communication oK xx faults saved
fault -- communication not oK or component module not nstalled