Hella Gutmann mega macs 42 Скачать руководство пользователя страница 24

24

Settings >Test function<

If no communication to the vehicle is established, use this programme to check the function of the diagnostic 

plug.

Steps:

Connect the mains supply to mega macs 42.

2. Select and confirm >Test function<. 

2. Connect the ST2 cable to mega macs 42.

4. Continue with 

The following messages can be displayed:

Diagnostic plug, cable or mega macs 42 defective.

or

mega macs 42 is OK.

Diagnostic socket inside the vehicle defective i.e. no voltage on pin 16 or rather poor earth connection on pin 4.

mega macs 42 Section D10 1/1

info message

a fault occurred 

line: 

a

range: 

1

number: 

1

nominal level 

1

actual level 

0

info message

test successfully done.

Содержание mega macs 42

Страница 1: ...User Manual mega macs 42 HBMM42V3400EN1008S0...

Страница 2: ...r battery pack B 9 10 Screen C 11 12 Settings Display D1 13 Company data D2 14 15 Version D3 16 Update D4 17 19 Printer Remote D5 20 Simulation D8 21 System parameters D9 22 air macs D10 23 Test funct...

Страница 3: ...every case Infringements are subject to sanctions of copyright law Hella Gutmann olutions GmbH cannot take guarantee for completeness up to dateness r orrectness regarding direct or indirect referenc...

Страница 4: ...urn out as wrong were incorrectly described or faults which by mistake appeared during data compilation Without restriction of the above mentioned facts Hella Gutmann Solutions accepts no liability fo...

Страница 5: ...up to several 100 C Always use safety equipment protective gloves etc Do not run connection lines near hot components Safety guidelines regarding explosion hazard Fuel vapours increase the risk of fi...

Страница 6: ...42 As every measuring device mega macs should also be handled with care Clean the device regularly with mild cleaning detergents Use commercial cleaning detergents and a moistened soft cleaning cloth...

Страница 7: ...ing fault codes Reading parameters and depicting them graphically Service reset Basic settings Coding mega macs 42 front TFT display and membrane keypad mega macs 42 bottom Connecting ports from left...

Страница 8: ...ery min 1000 mAh Display Type of construction LCD TFT Resolution 1 4 VGA Size approx 3 8 Storage medium Flash Input Membrane keypad Ambient temperature recommended 10 C 35 C Working area 0 C 45 C Weig...

Страница 9: ...e battery pack The battery pack is combined with the according electronics and cannot be repaired The batteries can be damaged by soldering or mechanical work Only insert the batteries which are offer...

Страница 10: ...e reverse order DISPOSAL OF USED BATTERIES ACCUMULATORS Batteries contain toxic substances Do not throw used batteries into household rubbish but dispose them accordingly Mask the terminals with insul...

Страница 11: ...e mega macs 42 Section C 1 2 Menu bar Footer macs 42 Diagnostics Peugeot 306 Diesel F3 Search 306 1 9 D WJY DW8 00 01 306 1 9 D DJZ XUD9Y 93 00 306 2 0 D HDI RHY DW10TD 99 01 306 1 9 TD DJY XUD9A 94 9...

Страница 12: ...ended by a text according to the selected menu which exemplifies the function Example F1 Info F3 Channel F2 opens a selection window The functions are called up depending on the menu point i e printin...

Страница 13: ...he brightness of the screen Steps 1 Select and confirm Display 2 Select brighter darker 3 Changing the setting Hold button pressed 4 Return with mega macs 42 Section D1 1 1 mega macs 42 Settings Displ...

Страница 14: ...X City Sampleville Company address Name 1 car dealership Name 2 Sample Street Sample street 5 Postal code 79XXX City Sampleville Brightness mega macs 42 Settings F1 Delete F3 Delete act UP Keypad Ente...

Страница 15: ...acs 42 Section D2 2 2 Info message Accept settings finally ENTER yes ESC no ESC ESC Brightness mega macs 42 Settings F1 Delete F2 Tab change F3 large small ESC Finish Street Sample street 5 ABC 123 A...

Страница 16: ...required by Gutmann mega macs 42 Section D3 1 1 Brightness Versions Overview Software 1 40 xx Data 34 xxx Design 1 4 31 xxx Hardware 1 xx Device number 12xx Access mask FFFxxx Programme Data version...

Страница 17: ...update licence of Gutmann Installation of Gutmann Portal on the PC free USB interface on the PC mega macs 42 voltage supply through mains supply Steps on the PC 1 Start the Internet browser on the PC...

Страница 18: ...18 4 Select and confirm mega macs 42 5 Confirm the message Click here to The PC is set up for data transmission mega macs 42 Section D4 2 4...

Страница 19: ...time Update Update Interface USB System check Update interface Automatic recognition RS232 USB air macs NOTE Automatic recognition mega macs 42 automatically searches for a connection RS 232 Only for...

Страница 20: ...y the screen contents of the mentioned diagnostic tools on the PC It also enables the operation of the diagnostic tools with the PC Selection of the PC interface assignment mega macs 50 Section D5 1 5...

Страница 21: ...firm Simulation 2 Select and confirm the function 3 Confirm the info message accordingly Attention If a vehicle is being connected when simulation is on no communication to the selected system will be...

Страница 22: ...arameters Charging condition of battery 45 Current battery 731 98 mA Voltage battery 11 54 V Voltage OBD 13 80 V Voltage mains supply 15 32 V Voltage UPOW 14 53 V Voltage 17 V 16 90 V Voltage 3 3 V 3...

Страница 23: ...g mega macs 42 and the Gutmann Portal Region settings The Region menu is used to set the country and language for mega macs 42 mega macs 50 Section D7 1 1 NOTE air macs PC search Assignment during the...

Страница 24: ...onnect the ST2 cable to mega macs 42 4 Continue with The following messages can be displayed Diagnostic plug cable or mega macs 42 defective or mega macs 42 is OK Diagnostic socket inside the vehicle...

Страница 25: ...Date The Date menu is used to set the date For proceeding see section Company address Settings Time The Time menu is used to set the time For proceeding see section Company address macs 42 Section D11...

Страница 26: ...are correctly assigned the vehicle is identified correctly Identify the vehicle as exactly as possible Voltage of vehicle electrical system is not lower 11 5 V If necessary use mains supply all power...

Страница 27: ...nter licence number Enter the licence number here to identify the vehicle in the diagnostic folder see section D2 macs 42 Section E 2 5 mega macs 42 Diagnostics Alfa Audi BMW Chrysler Citroen Daewoo P...

Страница 28: ...of the vehicle registration certificate Part 2 only for Germany Note Diagnostic programme There is an indication of the diagnostic types possible for the vehicle mega macs 42 Diagnostics Peugeot Dies...

Страница 29: ...ostic socket mega macs 42 Section E 4 5 mega macs 42 Diagnostics Peugeot Diesel 306 F1 Info F3 Search 306 2 0 D HDI RHY DW10TD 99 01 306 2 0 D HDI RHY DW10TD 99 01 306 2 0 D HDI RHY DW10TD 99 01 Peuge...

Страница 30: ...ga macs 42 Section E 5 5 Attention Follow the instructions on the screen without fail Note F1 Info Information about the selected system F2 Menu Information about the communication parameters Hella Gu...

Страница 31: ...o possible to directly read out the individual components Steps 1 Select the component module 2 Start the communication with F1 Steps for the individual component retrieval 1 Connect mega macs 42 as d...

Страница 32: ...on and or to register the position of the variable camshaft control CONSEQUENCE Poor starting behaviour etc REASON Interruption short circuit in electric circuit Note F1 System info Information about...

Страница 33: ...ample 2 Fault text incorrect lambda probe signal In both cases a diagnosis is possible only if the appropriate parameters are read out Mega macs 42 reads the parameters and displays them in plain text...

Страница 34: ...one group parameters required for diagnosis can be called up Info Channel RPM Fuel pressure Injection rate Accelerator position Group selection All parameters Basic function Engine start xxxxxx Chann...

Страница 35: ...or the parameters can be called up depending on manufacturer RPM Vehicle specific data Engine at operating temp idling 710 890 1 min Possible faults Idle actuator or TV actuator defective xxxxxx ESC C...

Страница 36: ...unctions and cable connections of those components Identification and communication establishment correspond to section E Danger Follow the instructions on the screen to avoid any damage of the system...

Страница 37: ...ment correspond to section E Manual reset 1 Select and confirm Service reset 2 Get further information by scrolling mega macs 42 Section J 1 2 Brightness geot Diesel 306 306 2 0D HDI RHY DW10TD Manual...

Страница 38: ...confirm the interval 2 Press F3 3 The reset will be done after establishing a communication Attention Follow the instructions on the screen without fail mega macs 42 Section J 2 2 Diagnostics Volkswa...

Страница 39: ...nd confirm System 2 Follow the instructions on the screen Attention The fault memory must be cleared before a basic setting Depending on the manufacturer the basic setting requires certain preconditio...

Страница 40: ...o section E Steps 1 Select and confirm System 2 Follow the instructions on the screen without fail Note F1 Help Information about the system and assistance for the coding procedure mega macs 42 Sectio...

Страница 41: ...d in the diagnostic folder The Diagnostic folder menu can be used to call up the stored vehicle data They can be displayed directly in mega macs 42 or printed out via PC with Gutmann Portal Connect th...

Страница 42: ...er Engine Note ENTER Load Indication of the marked entries in mega macs 42 3 Select and confirm Diagnostic type here fault code 4 Return with ESC Fault code overview Fault code 53528 CAN BUS disturbed...

Страница 43: ...Hella Gutmann Solutions GmbH Am Krebsbach 2 79241 Ihringen Germany Telephone 49 0 7668 99000 F 49 0 7668 9900 3999 info hella gutmann com www hella gutmann com...

Отзывы: