1 Assembly
1. Insert the column (1) with
the pressure disc (2) and the
clamping piece (3) into the
bush (4) einsetzen.
NOTE
The coloured
markings on the
column and the
base must be in line
with one another.
Tap the fixing pin (5) (fastened
to the base of the unit with
adhesive tape) into the drilled
hole in the column until the
two ends project the same
distance at either side.
2. Place the beamsetter box (6)
as shown in the illustration,
with the operating lever (7)
pressed down, and lower it to
the normal working height.
3. Set the sight holder (8) onto
the column and fasten it using
the locking wheel (9).
4. Press the hand-wheel
(10) down firmly onto the
hexagonal bar at the top end
of the column and secure it
with the knurled ring (11).
Opening for adjusting the column
guide, with 6 mm internal socket
spanner.
3