Err_check
l
Error Check
: This window shows both the present status of each error event and their history.
Current error event(s) can be reset by clicking
Erase Current Err!
button, and all error events
can be reset by clicking
Erase All!
button. List of the last ten drive faults. #0 being the most
recent, #9 is the oldest. See Figure 27.
Figure 27: Error check window
DM422 Digital Stepping Drive Manual V1.0
Toll Free 1-855-435-4958
29
OverCurrent:
Over-current Protection
. Protection will be activated when continuous current
exceeds 16A.
OverVoltage: Over-voltage Protection
. When power supply voltage exceeds 42
±
1 VDC, protection
will be activated.
PhaseErr:
Phase Error Protection
. Motor power lines wrong & not connected will activate this
protection.
ErrCounter:
Displays current error(s) and current error history.
Erase Current Err!: Erase Current Err
button. The user can clear current error(s) by clicking this
button.
Erase All!: Erase All!
button. The user can clear all error(s) including error history by clicking this
button.