SR100Hi Series 

-

 100 W DC UPS

 

The user is responsible for ensuring that input and output wiring segregation complies with local standards and that in the use of the equipment, 
access is confined to operators and service personnel.   A low resistance earth connection is essential to ensure safety and additionally, satisfactory 
EMI suppression (see below).

 

 

HAZARDOUS VOLTAGES EXIST WITHIN A POWER SUPPLY ENCLOSURE AND ANY REPAIRS MUST BE CARRIED OUT BY A 

QUALIFIED SERVICEPERSON.

 

  

 

Electrical Strength Tests

 

Components within the power supply responsible for providing the safety barrier between input and output are constructed to provide electrical 
isolation as required by the relevant standard. However EMI filtering components could be damaged as result of excessively long high voltage tests 
between input, output and ground. Please contact our technicians for advice regarding electric strength tests.

 

  

Earth Leakage

 

Where fitted, EMC suppression circuits cause earth leakage currents which may be to a maximum of 3.5mA. 

 

  

Ventilation 

 

High operating temperature is a major cause of power supply failures, for example, a 10

o

C rise in the operating temperature of a component will 

halve its expected life.   Therefore always ensure that there is adequate ventilation for the equipment.   Batteries in particular suffer shortened 
lifetimes if subjected to high ambient temperatures.

 

  

Water / Dust 

 

Every effort must be made in the installation to minimise the risk of ingress of water or dust. Water will almost always cause instant failure.   The 
effects of dust are slower in causing failure of electronic equipment but all electrical equipment should be cleaned free of any dust accumulation at 
regular intervals.

 

  

Electromagnetic Interference (EMI)

 

Switching power supplies and converters inherently generate electrical noise.  All wiring should be as short as practicable and segregated from all 
equipment wiring which is sensitive to EMI.   Residual noise can be reduced by looping DC wiring through ferrite cores (sleeves). These are most 
effective as close to the power supply as possible and as many turns of the wire taken through the core (+ and 

-

 in the same direction) as the core 

will accommodate. 

 

  

External fuse protection

 

Fuses or circuit breakers must be used in all battery circuits to protect against short circuits.   External fuses should  be used for power supplies/ 
chargers even though they are usually internally protected.

 

  

Connection polarity

 

It is critical to check the polarity carefully when connecting DC devices even with models which have non

-

destructive reverse polarity protection

.

 

1. SAFETY

 

Glossary of terms used in our user manuals

 

PSU 

= power supply unit

 

BCT

 = battery condition test

 

ECB

 = electronic circuit breaker

 

ELVD

 = electronic low voltage disconnect

 

RPP

 = reverse polarity protection

 

EMI

 = electromagnetic interference

 

SNMP

 = Simple Network Management 

 

Protocol  

 

EMC

 = Electromagnetic compatibility

 

DOD

 = depth of discharge

 

Содержание SR100Hi Series

Страница 1: ...rm C Float Charger Lead Acid Batteries ELVD Electronic low voltage disconnect Temperature Sensor on 1 7m lead with adhesive pad 4mV C cell 10 N 1 Redundancy Comms RS232 RS485 Modbus SNMP Webpages Cust...

Страница 2: ...2 www heliosps com...

Страница 3: ...BLOCK DIAGRAM 5 4 OPERATION OF ELECTRONIC CIRCUIT BREAKER ECB FOR PROTECTION OF BATTERY CIRCUIT BATTERY 5 5 FRONT PANEL LAYOUT 6 6 CONNECTION AND INITIAL TESTING 7 7 LED INDICATION 7 8 SR100Hi DC SET...

Страница 4: ...h ambient temperatures Water Dust Every effort must be made in the installation to minimise the risk of ingress of water or dust Water will almost always cause instant failure The effects of dust are...

Страница 5: ...together when there is no input power Max allowable load amps x I rated 8 7 2 5 2ms 300ms Time ECB automatically resets IPSU 1x I rated 7x I rated for 300ms max 2 5 x I rated until battery fully dis...

Страница 6: ...r present Battery Missing or fault in battery circuit wiring alarm does not activate for up to battery detection interval time BCT fail 4 LOAD BATTERY CONNECTION 5 LED indications Batt OK and Power OK...

Страница 7: ...the B and B terminals 8 Turn on ac power 9 After the batteries are fully charged check that the battery continues to power up the load when the input power is turned off Power OK LED Battery OK LED P...

Страница 8: ...AT LOW alarm shows Vshutd Internal voltage level of the power supply during battery detection and battery condition tests Vbatl BAT LOW alarm voltage level Vdisco Voltage at which the load is disconne...

Страница 9: ...B is one stud labelled COMMON Alarms Available Input Fail YES Battery Missing YES Battery Low YES Battery Condition Test Fail YES ALARMS ECB LVD INPUT L B L SRxxx Hi B LOAD Peak load connection using...

Страница 10: ...B BATT2 1 interlock circuit required for automated BCT use SR100 Hi chargers 10 MODEL CODING AND OPTIONS T Yes Blank No Temperature Compensation 12 24 30 36 48V DC output nominal battery voltage Funct...

Страница 11: ...esive pad 4mV C cell 10 Battery Charge Current Limit Customizable on request Reverse Polarity Battery reverse connection will open internal fuse and produce alarm Battery Monitoring Detects for presen...

Страница 12: ...arrants this product for 24 months from date of shipment against material and workmanship defects Liabil ity under this warranty is limited to the replacement or repair of the defective product as lon...

Отзывы: