1.10 Electrical connection
All work must be carried out with the equipment fully isolated from the power supply. The electrical connection
are to be carried out in accordance with the relevant wiring diagram and are only to be done by a certified elec-
trician.
The electrical connection must be fully isolated from the supply up to the final assembly!
All relevant safety regulation, national standards and norms are to be adhered to. An appliance is required for cut off
from the supply with a minimum of 3 mm contact opening of each pole. The speed controller KWL 60 BC.. is connec-
ted by means of control cable with the fan unit. The mains supply cable (flexible cable) is attached at the female plug
(see page 4, wiring diagram SS-950 / SS-958).
1.11 Technical data
Votage/Frequency
230 V~/50 Hz
Wiring diagram
SS-950
Rated current A
0,06
Temperature operating range
-20 °C - 40 °C
Protection to
IP X4
Weight of First fix set
3,25 kg
Electrical connection
NYM-J 3 x 1,5 mm
2
Weight of fan unit
5,55 kg
Mains supply cable via flexible cable
2 x 1,5 mm
2
1.12 Accessories
KWL 60 WV
Ref.No. 0884
Extension sleeve
for wall thickness > 350 mm
KWL 60 DR
Ref.No. 0888
Compensation ring
for outside wall for wall thickness < 350 mm
KWL 60 BCU
Ref.No. 9955
Speed controller for flush mounted installation
with 3 m connecting cable
KWL 60 BCA
Ref.No. 9956
Speed controller for surface mounted installation
with 3 m connecting cable
KWL-CO
2
Ref.No. 9958
CO
2
-Fühler
, measures CO
2
concentration
KWL-ALA
Ref.No. 9460
Wye junction board
to connect further units or controllers
KWL 60 AL 10
Ref.No. 9444
Connecting cable
10 m
KWL 60 AL 20
Ref.No. 9959
Connecting cable
20 m
Filter
(see page 5)
2.0
Scope of delivery / packing unit
Leave the fan in its box until installation. Check that the fan is in good condition and has not been damaged in transit.
Coordinated on the individual assembly steps the following elements are to be ordered separately:
- First fix set KWL 60 RS
Ref.No. 0708
- Ventilation unit KWL EC 60 Pro
Ref.No. 9951
- Ventilation unit KWL EC 60 Pro FF
Ref.No. 9957
- Extension sleeve
Ref.No. 0884
- Compensation ring
Ref.No. 0888
fig.3
KWL 60 DR
fig.4
20
18
Wall installed unit KWL EC 60 Pro / ... Pro FF
Installation and Operating Instructions
First fix set
➍
➊
fig.1
➋
CHAPTER 2
SCOPE OF DELIVERY /
PACKING UNIT
➌
WARNING
Ventilation unit
➎
fig.2
➐
➑
➌
➌
➌
➒
➓
11
12
➏
➊
External facia
made from high grade steel
➋
Drill jig
➌
Protection cover plate
incl. polystyrene support
➍
Wall sleeve
➎
Sealing strip
➏
Plastic plug
➐
Drainboard
➐
Indoor facia from high quality polymer
➑
2x filter G4
in supply and extract air stream
➒
Ventilation unit
with aluminium plate heat exchanger
➓
Plastic screws
Plug, mains supply line
Jack, control cable
Wall sleeve
2x partition element
Extension hose
condensate removal
Compensation ring from high grade steel
Wall sleeve
2x partition element
Extension hose
condensate
removal
Fastening screws
for external facia
(from high grade
steel)
11
12
19
17
16
16
17
18
19
20
13
14
15
14
15
13
UK
additionally with
comfort controller
KWL-BCU incl. 3 m
connection cable.