1
Safety
Safety
Information
Information
The connection and installation of electrical
appliances must be performed by a skilled
electrician only. Any intervention into or
modifications to the appliance shall lead to
the lapse of all warranty rights. Comply with
your national regulations and all relevant
safety stipulations.
Display of special functions:
Permanent ON/OFF
Holiday program
active
Displayed only when summer/
winter time changeover is
activated
Summer time
Winter time
@
Current days of the week
1
= Monday,
2
= Tuesday, ...
The decision
Yes
confirms the
selection or programming
Decision
No
means continue
Overview per day of the
programmed
switching times
5 = Friday
Channel
statuses
/
Service voltage OK
Two flashing dots.
Power reserve mode
Three flashing dots.
Selection
e.g.: Auto, Prog.
Abort input
D
GB
F
309 806_03
KWL-WSU
Art. no.
00856.002
WSUP
Art. no.
09990.001
Type KWL-WSU
Version
KWL 230 Roto
ex Vers. 001
KWL 250 ..
all
KWL 350 ..
ex Vers. 001
KWL 650 ..
ex Vers. 001
Type WSUP
Version
KWL EC 200 Eco
ex Vers. 001
KWL EC 300 Eco
ex Vers. 001
KWL EC 500 Eco
ex Vers. 001
1. Intended use
The clock timer is suitable for flush mounted installation in dry rooms. It regulates a week program
and takes over the controlling of the setback operation.
Mode of operation WSUP:
ON = Change-over contact can be used freely
(see page 7)
OFF = Change-over contact can be used freely
(see page 7)
Mode of operation KWL-WSU: ON = Normal operation
(controlling via operation switch, o. switch ON)
The KWL-unit is operated in the performance level activated at the operati-
on switch. With two-stage KWL operation the switching occurs into the
high performance level.
OFF* = Setback operation
(controlling via KWL-WSU, o. switch OFF)
KWL is operated on the lowest performance level.
* With OFF the display does not correspond to the current performance level. On the operation switch the
performance level is always shown, which is again activated after the setback operation. The setback
operation can comfortably be determined in the normal "standard program" of the clock timer.
2. Features
Reset
●