background image

Fensterventilator GX 150
Window fan GX 150
Ventilateur de fenêtre GX 150

2

Fig.3

Fig.4

Fig.6

Fig.7

L

B

E

K

A

H

D

C

M

K

G

J

N

(f)

Fig.1

Fig.2

210

230

105

40

145

184

(b)

(a)

(d)

(c)

Fig.5

Fig.8

A

Verschlussklappe / Back draught shutter / Volet de fermeture anti-refoulement

B

Ventilator / Fan Assembly / Ensemble extracteur

C

Außengitter / Outer Grille / Grille extérieure

D

Schraubbänder / Ladder strips / Eléments d’échelle

E

Klemmenabdeckungen / Terminal cover / Cache-borne

G

Hintere Ausbrechstelle für Kabeldurchführung / Rear cable entry knockout /
Entrée défonçable arrière de câble

H

Obere Kabeleinführung / Top cable entry / Passage supérieur de câble

J

Leistungsschild / Rating Plate / Plaque signalétigue

K

Befestigungslaschen für die Schraubmontage / Lugs for Screw Mounting /
Pattes pour fixation par vis

L

Gitter / Grille / Grille

M

Schraubenabdeckungen / Screw Covers / Cache-vis

N

Laufrad / Impeller / Hélice

Содержание GX 150

Страница 1: ...ration are not liable for warranty INSTALLING THE FAN These products are intended for connection to fixed wiring Check that the electrical rating shown on the fan matches the mains supply All installations must be supervised by a qualified elec trician Installations and wiring must conform to cur rent Regulations local or appropriate regulations Warning These appliances must be earthed OPERATION U...

Страница 2: ... Grille extérieure D Schraubbänder Ladder strips Eléments d échelle E Klemmenabdeckungen Terminal cover Cache borne G Hintere Ausbrechstelle für Kabeldurchführung Rear cable entry knockout Entrée défonçable arrière de câble H Obere Kabeleinführung Top cable entry Passage supérieur de câble J Leistungsschild Rating Plate Plaque signalétigue K Befestigungslaschen für die Schraubmontage Lugs for Scre...

Страница 3: ...ocated at least 145 mm from the edges of the Wall Check there are no buried pipes or cables in the wall or obstructions on the outside e g Electricity Gas Water Mark on the wall the centre of the hole and drill right through Use this hole to draw a circle 184 mm Diameter Cut the hole Do not cut right through the wall The recommended method is to drill a series of holes close together around the ed...

Страница 4: ... knock out Feed the cable through the knock out If wiring from above remove the Fan s Terminal Cover and feed the cable through the top cable entry Hold the Fan assembly to the inside of the wall so that the spigot is inserted into the wall duct Mark the positions of the two fixing holes in the top left and bottom right corners Remove the Fan assembly drill the holes and ins ert anchor fixings app...

Страница 5: ...ble and clam ping of the cable wires Start operation only if protection against accidental contact with impeller is guaranteed Check air flow direction LOOKING AFTER YOUR FAN Cleaning recommended once a month Before cleaning isolate the Fan on all poles from the mains supply Allow 30 seconds for the impel ler to stop on the Fan and 3 minutes for the im peller to stop and the powered shutter to clo...

Страница 6: ... SB 50 2 Order ref 1385 WARRANTY EXCLUSION OF LIABILITY If the preceeding instructions are observed all war ranty claims and accommadation treatment are exclu ded This also applies to any liability claims extended to the manufacturer REGULATIONS The product complies with all relevant international regulations if all instructions are followed Druckschrift Nr 90 694 12 02 ZUBEHÖR SCHALT UND STEUERGE...

Отзывы: