Helios Power Solutions TDK-Lambda PFE700SA Series Скачать руководство пользователя страница 6

 

TDK-Lambda 

 PFE700SA Series 
INSTRUCTION MANUAL

 

 
 
 
 

 

F1 : External Input Fuse 

PFE700SA Series has no internal fuse. Use external fuse to acquire each Safety Standard and to further 
improve safety. PFE700SA Series acquired safety standard certification using 15A, 250V, Fast-Blow 
external fuse. Further, Fast-Blow type fuse must be used per one module. Also, in-rush surge current flows 
during line throw-in. Be sure to check I

2

t rating of external switch and external fuse. 

 

Recommended External Fuse

15A , 250V  

 
Note)

 

Select fuse based on rated voltage, rated current and surge current capability. 

 

 

 (1) Voltage Ratings 

100VAC line : AC125V 
200VAC line : AC250V 

 

(2) Current Ratings 

Rated current is determined by the maximum input current based on operating conditions and can be 
calculated by the following formula. 

 

         

(Arms)

 

PF

η

Vin

Pout

(max)

Iin 

´

´

=

  (Formula 5-1) 

 

Iin (max)  :  Maximum Input Current 
Pout      

:  Maximum Output Power 

Vin            :  Minimum Input Voltage 
η            

 

 :  Efficiency 

PF       

:  Power Factor 

 

For Efficiency and Power Factor values, refer to separate document “PFE700SA Evaluation Data”

.

 

 

C1, C4, C5 : 1uF (Film Capacitor) 

Ripple current flows through this capacitor. When selecting capacitor, be sure to check the allowable 
maximum ripple current rating of this capacitor. Verify the actual ripple current flowing through this 
capacitor by doing actual measurement. 
Connect C5 as close as possible towards the input terminals AC(N) and AC(L) of this power module. 
 

Recommended Voltage Rating : 250VAC 

 
L1, L2 : 6mH 

Add common mode choke coil as EMI/EMS countermeasure. When using multiple modules, connect coil to 
each module. 
 
Note)

  

Depending on the input filter used, noise might increase or power module might malfunction due to 

filter resonance. 

 

C2, C3 : 4700pF(Ceramic Capacitor) 

Add ceramic capacitor as EMI/EMS countermeasure. Be sure to consider leakage current of your equipment 
when adding this capacitor. 
High withstand voltage are applied across this capacitor depending on the application. Select capacitor with 
high withstand voltage rating. 

 
 
 
 
 
 

Содержание TDK-Lambda PFE700SA Series

Страница 1: ...umidity should be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatm...

Страница 2: ...mation in this document is subject to change without prior notice Please refer to the latest version of the data sheet etc for the most up to date specifications of the product No part of this documen...

Страница 3: ...der contact resistance when connecting AC L AC N R BC BC V V Note that BC and BC terminal are primary voltage with high voltage 375VDC Do not connect load from these terminals Do not make external con...

Страница 4: ...ier Output filter Switching Frequency PFHC Circuit fixed 100kHz DC DC Converter Circuit fixed 180kHz primary 360kHz secondary 4 Sequence Time Chart Input Line ON OVP Acitivate Input Line Cut off Input...

Страница 5: ...l components according to Fig 5 1 Pay attention to the each wiring If it is connected to wrong terminal the power supply will be damaged PFE700SA Series employs conduction cooling method Use heat sink...

Страница 6: ...Vin Minimum Input Voltage Efficiency PF Power Factor For Efficiency and Power Factor values refer to separate document PFE700SA Evaluation Data C1 C4 C5 1uF Film Capacitor Ripple current flows through...

Страница 7: ...1 390uF Electrolytic Capacitor Refer to Selection Method of External Bulk Capacitor for Boost Voltage below Allowable external capacitance at nominal capacitance value is shown below Recommended Volta...

Страница 8: ...capacitor Also note that output ripple voltage may vary depending on the wiring pattern of the printed circuit board Sudden change in output voltage due to sudden load change or sudden input voltage c...

Страница 9: ...r with higher ripple current rating 0 500 1000 1500 2000 2500 0 100 200 300 400 500 600 700 Ripple Current mA rms Output Power W 100VAC 200VAC Fig 5 2 Allowable ripple current value The recommended bo...

Страница 10: ...n R Formula 5 2 R Resistance Value for External TFR1 Vin Input Voltage converted to DC value Input Voltage rms x 2 Irush Input surge current value 2 Required Surge Current Rating Sufficient surge curr...

Страница 11: ...cover output by recycling input line OVP value is fixed and cannot be set externally Pay attention not to apply higher voltage externally to the output terminal to avoid power supply damage 6 4 Over C...

Страница 12: ...e including Spike Noise Measurement Method 6 8 Parallel Operation Output current sharing through parallel operation is possible for PFE700SA Series by connecting the output terminal For maximum output...

Страница 13: ...plate and Input Output do the withstand voltage test after setting current limit value of the withstand voltage testing equipment to 20mA Be sure to apply DC voltage between Output base plate Avoid ap...

Страница 14: ...3 C6 C7 C14 Capacitor of Output Base plate C12 C13 7 Mounting Method 7 1 Mounting Method These products can be used in any orientation but be sure to consider enough airflow to avoid heat accumulation...

Страница 15: ...plate and Ambient Temperature 85 85 Fig 7 3 Derating Curve Load v s Baseplate and Ambient Temperature 0 20 40 60 80 100 80 100 120 140 160 180 200 220 240 260 Load Input voltage VAC Tbp less than 85 T...

Страница 16: ...rance between the primary and the secondary In order to acquire safety standards for this power module creepage distance and clearance between the primary and the secondary is designed to be 7 5 mm Th...

Страница 17: ...d Is the actual baseplate temperature within the specified operating temperature of this module 2 Output voltage is low Is specified input voltage applied Is there no abnormality with the output load...

Отзывы: