7-4. Recommended Soldering Condition 

Recommended soldering temperature is as follows. 
Soldering Dip         

260

, within 10 seconds 

Preheat           

    :

130

, within 60 seconds 

 

7

-5. Recommended washing Condition

 

After soldering, following washing condition is recommended. 
For other washing conditions, consult our Customer Support Group. 

     

(1)

 

Recommended washing solution 

    ・

IPA

Isopropyl Alcohol

 

     

(2)

 

Washing method 

         

In order to avoid penetration inside the power module, washing should be done with brush. 
Then, dry up thoroughly after washing. 

 
 

8. Before Concluding Power Module Damage 

Verify following items before concluding power module damage. 
 
(1) No output voltage 
- Is specified input voltage applied? 
- Is there no abnormality with the output load? 
- Is the actual baseplate temperature within the specified operating temperature of this module? 
 
(2) Output voltage is low 
- Is specified input voltage applied? 
- Is there no abnormality with the output load? 
 
(3) Load regulation or line regulation is large 
- Is specified input voltage applied? 
- Are the input or output terminals firmly connected?  
- Are the input and output wires too thin? 
 
(4) Large output ripple 
- Is the measurement done according to methods described in the Instruction Manual or is it an equivalent 

method? 

 
 

9. Warranty Period 

Warranty period is 5 years. 
For damages occurring at normal operation within this warranty period, repair is free of charge.  
 
Following cases are not covered by warranty 
(1)

 

 Improper usage like dropping products, applying shock and defects from operation exceeding 

     

specification of the unit. 

(2)

 

 Defects resulting from natural disaster (fire, flood etc.) 

(3)

 

 Unauthorized modifications or repair by the buyers’ defects not cause by our company. 

Содержание TDK-Lambda PFE700SA Series

Страница 1: ...umidity should be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatm...

Страница 2: ...mation in this document is subject to change without prior notice Please refer to the latest version of the data sheet etc for the most up to date specifications of the product No part of this documen...

Страница 3: ...der contact resistance when connecting AC L AC N R BC BC V V Note that BC and BC terminal are primary voltage with high voltage 375VDC Do not connect load from these terminals Do not make external con...

Страница 4: ...ier Output filter Switching Frequency PFHC Circuit fixed 100kHz DC DC Converter Circuit fixed 180kHz primary 360kHz secondary 4 Sequence Time Chart Input Line ON OVP Acitivate Input Line Cut off Input...

Страница 5: ...l components according to Fig 5 1 Pay attention to the each wiring If it is connected to wrong terminal the power supply will be damaged PFE700SA Series employs conduction cooling method Use heat sink...

Страница 6: ...Vin Minimum Input Voltage Efficiency PF Power Factor For Efficiency and Power Factor values refer to separate document PFE700SA Evaluation Data C1 C4 C5 1uF Film Capacitor Ripple current flows through...

Страница 7: ...1 390uF Electrolytic Capacitor Refer to Selection Method of External Bulk Capacitor for Boost Voltage below Allowable external capacitance at nominal capacitance value is shown below Recommended Volta...

Страница 8: ...capacitor Also note that output ripple voltage may vary depending on the wiring pattern of the printed circuit board Sudden change in output voltage due to sudden load change or sudden input voltage c...

Страница 9: ...r with higher ripple current rating 0 500 1000 1500 2000 2500 0 100 200 300 400 500 600 700 Ripple Current mA rms Output Power W 100VAC 200VAC Fig 5 2 Allowable ripple current value The recommended bo...

Страница 10: ...n R Formula 5 2 R Resistance Value for External TFR1 Vin Input Voltage converted to DC value Input Voltage rms x 2 Irush Input surge current value 2 Required Surge Current Rating Sufficient surge curr...

Страница 11: ...cover output by recycling input line OVP value is fixed and cannot be set externally Pay attention not to apply higher voltage externally to the output terminal to avoid power supply damage 6 4 Over C...

Страница 12: ...e including Spike Noise Measurement Method 6 8 Parallel Operation Output current sharing through parallel operation is possible for PFE700SA Series by connecting the output terminal For maximum output...

Страница 13: ...plate and Input Output do the withstand voltage test after setting current limit value of the withstand voltage testing equipment to 20mA Be sure to apply DC voltage between Output base plate Avoid ap...

Страница 14: ...3 C6 C7 C14 Capacitor of Output Base plate C12 C13 7 Mounting Method 7 1 Mounting Method These products can be used in any orientation but be sure to consider enough airflow to avoid heat accumulation...

Страница 15: ...plate and Ambient Temperature 85 85 Fig 7 3 Derating Curve Load v s Baseplate and Ambient Temperature 0 20 40 60 80 100 80 100 120 140 160 180 200 220 240 260 Load Input voltage VAC Tbp less than 85 T...

Страница 16: ...rance between the primary and the secondary In order to acquire safety standards for this power module creepage distance and clearance between the primary and the secondary is designed to be 7 5 mm Th...

Страница 17: ...d Is the actual baseplate temperature within the specified operating temperature of this module 2 Output voltage is low Is specified input voltage applied Is there no abnormality with the output load...

Отзывы: