48
232
KEYOFF
SHORTED
Short circuit
of key switch
At start-up stage, if controller detects that there is low
logic level signal when key switch is off, there is a fault.
Fault analysis: Most possibly is that the voltage is
excessively low, suggest to check the followings :
(1) If the key switch is based on external load (e.g. the
starting of DC-DC converter, the input signal of relay or
contactor switch is lower than starting voltage).
(2) Check the positive and negative poles of power cable
and cell end and the connection between –BATT and
+BATT of main contactor and controller. It must be
connected with screw and the torsion scope is
13NM~15NM..
(3) If no voltage drop has been detected on the power
supply line, the fault signal is produced every time when
the key switch is on. The fault may be possibly in the
hardware of the controller; therefore, the controller needs
to be changed.
233
POWER MOS
SHORTED
Short circuit
of power
MOS
Software will check the power bridge before main
contactor is closed: It converts into low-end power of
MOS and the phase voltage value drops to –BATT (rise to
+BATT). If the change of phase voltage value does not
conform to the instruction, this fault signal is produced.
Change the controller.
235
HANDBRAKE
Fault of
handbrake
switch
Handbrake input signal is valid when the running
instruction is issued.
Resolution
:
Possible causes for the fault :
(1) Handbrake switch is damaged or wiring is wrong.
(2) Handbrake switch works normally. In TESTER menu,
handbrake is always ON. This is a logic fault, so change
the controller.
236
CURRENT
GAIN
Fault of
current gain
The maximum current gain parameter is a factory set
value, which indicates that the max. current regulating
parameter program has not be used.
Resolution: Correctly set program for current gain
parameter by ZAPI technical personnel.
237
ANALOG
INPUT
Fault of
Analog Input
The fault signal is produced when A/D of all analog
signals is converted into a fixed value and delay exceeds
400 millisecond. This function is used to check the fault
of A/D converter or analog signal conversion.
Fault analysis: Change the controller if the fault always
exists.
238
WRONG ZERO
VOLTAGE
Wrong Zero
Voltage
During startup, the feedback value of high end voltage of
VMN is not at about 2.5V. The circuit of controller is
damaged.
Fault analysis : The following checks are suggested:
(1) Internal connection of motor.
(2) Power cable connection of motor.
(3) Drain current between motor and vehicle casing.
(4) If the motor connection is good, the problem is inside
the controller and changes it.
239
SAFETY
Failure of
Driver short circuit of safety output.
Содержание CPD15
Страница 1: ......
Страница 9: ...7 Ⅱ Main Specifications of Forklift Truck Enternal view of forklift trucks ...
Страница 28: ...26 Figure 4 1 Electric system principle diagram CPD15SQ 20SQ GB2Li 1M1 2M1 μ ú é è ...
Страница 32: ...30 Figure 4 5 CPD15SQ GB2Li control device assembly ...
Страница 33: ...31 Figure 4 6 CPD16SQ GB2Li control device assembly ...
Страница 34: ...32 Figure 4 7 CPD18 20SQ GB2Li control device assembly ...
Страница 90: ......