![Helen of Troy Kaz Stinger FP15 Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/helen-of-troy/kaz-stinger-fp15-series/kaz-stinger-fp15-series_owners-manual_2120485003.webp)
TROUBLESHOOTING
Symptom:
Solution:
Unit will not light, no apparent grid voltage
- Make sure unit is plugged into working outlet.
Unit will not light, grid has voltage
- Check bulb to make sure it is seated properly.
- Replace bulb if necessary.
Unit appears to be working properly but insect
- Check surrounding area for sitting water, insects breed in these areas and should be eliminated from the source.
populations do not seem reduced
- Allow more time; it will take some time for the insects to find the unit and also for there to be an impact on their reproductive cycles.
- Try moving the unit to another area of the yard. If you are in between the unit and the source of the insects, they will have to fly by you to get to the
unit and you may actually notice an increase in insects.
Unit is constantly Arcing (sparking)
- Clean unit per the instructions in the “Cleaning” section of this manual.
If the above troubleshooting doesn’t solve your problems or you have any other questions, please call consumer relations at 1-800-477-0457 or email [email protected]
CHOOSING A LOCATION
When selecting a location, you want to remember insects will be lured to the unit so do not put the unit near human activity. Choose a
location about 25 feet away from the area you are trying to protect. If there is a water source nearby, place the unit between you and the
water because water is a breeding ground for most flying insect pests. The FP15 is designed to cover up to 1/2 acre. (Fig. 1)
INSTALLATION/OPERATION
1. Unpack unit, save all packaging material for off-season storage.
2. Select the proper location to hang your unit using the information above.
3. Hang the unit approximately 7 feet above the ground from a tree, mounting pole or other free standing object. Never mount the unit
from house or other building.
4. Plug cord into a compatible extension cord rated for outdoor use.
5. The unit will be on once it is connected to an electrical source. This unit does not have an “on/off” switch. Please allow up to 5
minutes for the bulb to light completely.
6. This unit is designed to withstand moderate rains but should be taken down and stored indoors during severe weather.
7. It is recommended that this unit be put into use in early spring and left out until late fall to maximize effects.
TO USE NOSQUITO
®
by Stinger OCTENOL LURES
(Octenol Lure not included. Sold separately; see participating retailer or call Consumer Relations at 1-800-477-0457)
Use of NOsquito
®
by Stinger Octenol Lures can improve the performance of this product. Use only NOsquito
®
by Stinger lures. Research
has shown that octenol is effective in attracting many species of mosquitoes and biting flies. Lures have slow release properties and
can increase the effectiveness of attracting mosquitoes to the unit. For best results, replace every 30 days. This product has a specially
designed lure holder built into the left upper side of the unit to hold a NOsquito
®
by Stinger Octenol Lure (NS16).
1. To install; peel off the foil lid.
2. Open the small door with a finger nail or flat screwdriver and simply push the lure into this holder with holes
facing in. The lure should fit snuggly and the tension tabs should hold it tightly in place. Shut the door until it
securely snaps in place. (Fig. 2)
3. To remove – pull out the lure and discard appropriately in a trash receptacle.
CHANGING BULBS
Only use Stinger
®
replacement bulbs. White UV (B1515) or Black UV (B1515-BL) are available. These bulbs should be replaced
annually to maintain optimal UV effectiveness. Even though the bulb’s light may be visible to you, its ability to attract insects diminishes
over time. If the bulb fails to light or the color of the light changes to yellow or orange it is time to replace the bulb. (Fig. 3)
1. Unplug and remove entire unit from hanging position.
2. The FP15 has a specially designed bulb holder built into the right upper side of the unit. Open the small door with a finger nail
or flat screwdriver.
3. Insert the new bulb making sure it is properly seated in the socket.
4. Shut the door until it securely snaps in place.
5. Place unit back into the hanging position and plug back into the outlet.
NOTE:
The bulb in this unit contains Mercury, dispose according to Local, State or Federal Laws.
IMPORTANT:
If unit fails to light after replacing bulb, take unit down and remove the bulb and reseat it in the socket.
CLEANING
As the unit kills insects, most of the insect remains will be vaporized or fall down through the unit. Some remains will be left on the grids
and over time will reduce the effectiveness of this device. Make sure to regularly clean your unit to achieve maximum effectiveness. The time
in between each cleaning will vary depending on your insect populations. Check your unit frequently and clean any insect remains you see.
1. Unplug and remove entire unit from hanging position.
2. Remove bulb from unit to avoid damage (see above instructions).
3. Using a small brush or stick, gently remove any insect remains from outer casing and inner grids.
4. If available, you may use compressed air to clean out your unit.
5. Never use water to clean your unit, water could damage the electrical components.
6. Once the unit is clean, replace the bulbs, return the unit to the hanging position and reconnect to power source.
NOTE:
If arcing (sparking) occurs after cleaning, unplug unit and remove from hanging position. Check the grids and make sure
they are not touching in any place. Gently use a stick to bend grids away from each other.
Figure 1
Figure 2
Figure 3
Model NS16