| 10. Status signals
10. Status signals
In normal operation, the smoke
alarm carries out an automatic
self-check in regular intervals.
The corresponding status is
signalised by means of the test
button and the acoustic alarm.
Normal operation
The smoke alarm has an integrated
real-time clock. This has the effect
that the LED in the test button and
the acoustic alarm are deactivated
from 9 p.m. to 7 a.m. CET
1
.
Test button
Acoustic alarm
Cause
Remedy
GREEN
Flashes every
48 seconds
---
Smoke alarm
functions
impeccably
---
GREEN
Flashes every
48 seconds
Short acoustic
signal every
60 seconds
Fault of a smoke
alarm in the line
Locate the
smoke alarm
with the fault.
Rectify the fault.
Re-commission
radio module.
GREEN-
ORANGE-
RED
Running
light every
48 seconds
---
Radio networking
is not possible ( up
to max. 2 hours
after insertion of
the radio modules )
Commission the
radio module.
Continued on page 25
1
CET: Central European Time (winter time)