Heinrichs KDSE Скачать руководство пользователя страница 3

 
 
 
Heinrichs Messtechnik GmbH 

Ex- Supplement operating manual KDSE 

Page 3 of 14 

 

Introduction 

I.

 

Shipping and storage; product inspection 

The device is to be safeguarded against moisture, dirt, impact and damage. 
Product inspection 
Upon receipt of the product, the consignment should be checked for

 

completeness. The data of the device have 

to be compared with the packing slip and the order documents 
Notify us of any shipping damage immediately upon receipt of the product. Any damage claim received at a later 
time will not be honored. 

II.

 

Warranty 

Your flow meter was manufactured in accordance with the highest quality standards and was thoroughly tested 
prior to shipment. However, in the event any problem arises with your device, we will be happy to resolve the 
problem for you as quickly as possible under the terms of the warranty which can be found in the terms and 
conditions of delivery. Your warranty will only be honored if the device was installed and operated in accordance 
with the instructions for your device. Any mounting, commissioning and/or maintenance work is to be carried 
out by qualified and authorized technicians only. 

III.

 

Validity of this operating manual 

The present instructions apply to explosion-proof transmitter type KDSE as of year of construc-
tion February 2021 
These instructions are supplementary operating manual for non-explosion proof meters. If you 
do not have a copy of the latter instructions, please request one from Heinrichs Messtechnik 

GmbH or download the instructions from our website.  
The instructions herein pertain primarily to explosion proof magnetic-inductive flow meters. The technical data 
in the mounting and operating instructions for non-explosion proof magnetic-inductive flow meters still apply 
insofar as the present instructions do not replace them or exclude their application. 

IV.

 

Returning the device for repairs or servicing 

Note: According to German waste disposal legislation, it is the owner’s or customer’s responsibility to dispose 
of hazardous waste. Thus, before any devices are returned to Heinrichs Messtechnik for servicing or repairs the 
following measures must be performed: 

 

When returning the unit for an inspection, please enclose as detailed a description as possible of the fault 

and the specific application, as well as the chemical-physical properties of the measurement medium. 

 

Remove all residue of measurement medium which may be present. paying special attention to the gasket 

grooves and crevices. This is especially important if the medium is detrimental to health and safety, for 
example: corrosive, poisonous, carcinogenic or radioactive etc. 

Costs, which result from insufficient cleaning, (disposal and/or personal injuries) will be invoiced to the cus-
tomer. 

 

Содержание KDSE

Страница 1: ...nuary 2021 Electronic transmitter KDSE EX Supplementary Operating Manual for Hazardous areas Safety Instructions This operating manual is a supplement to the manuals for the Flow meters KDS und BGK Pl...

Страница 2: ...aintenance 4 1 2 Hazard warnings 5 1 3 Proper use of the device 5 2 Identification 6 3 General information about explosion protection 7 4 Applications 8 5 Operational mode and system design 8 6 Electr...

Страница 3: ...ruc tion February 2021 These instructions are supplementary operating manual for non explosion proof meters If you do not have a copy of the latter instructions please request one from Heinrichs Messt...

Страница 4: ...y maintenance or repair which is safety relevant in terms of explosion protection is to be carried out by the manufacturer an authorized Heinrichs Messtechnik GmbH service center or under the supervis...

Страница 5: ...l material damage or even death Always comply to these warnings and proceed with caution Caution means that failure to take the prescribed precaution could result in material damage or de struction of...

Страница 6: ...hs Messtechnik GmbH Robert Perthel Strasse 9 D 50739 Cologne Germany Phone 49 221 49708 0 Fax 49 221 49708 178 Internet www heinrichs eu Email info heinrichs eu Product type Electronic transmitter for...

Страница 7: ...o occur 3G 2 3D 22 Equipment in this category is intended for use in areas in which explosive atmospheres caused by gases vapours mists or air dust mixtures are unlikely to occur or if they do occur a...

Страница 8: ...ion of a magnet in the variable area flow meters series KDS and BGK Either the position of the float in which there is a permanent magnet or the angular position of a ring magnet which is located on a...

Страница 9: ...as described below 6 1 Electrical and thermal parameters Voltage Ui DC 30 V Current Ii 150 mA Effective internal inductance Li 0 24 mH Effective internal capacitance Ci 15 nF Power Pi in acc with the...

Страница 10: ...g tube 7 3 Ground connection In variable area flow meters it is possible under operating conditions for charge separation to occur in the measuring tube due to the transport of non conductive fluids a...

Страница 11: ...age 11 of 14 8 Marking Warning Only devices with ex marking may be operated within the explosive atmospheres range The electronic module is marked as follows When the module is assembled in a variable...

Страница 12: ...Heinrichs Messtechnik GmbH Page 12 of 14 Ex Supplement operating manual KDSE 9 Declaration of Conformity...

Страница 13: ...Heinrichs Messtechnik GmbH Ex Supplement operating manual KDSE Page 13 of 14...

Страница 14: ...Heinrichs Messtechnik GmbH Page 14 of 14 Ex Supplement operating manual KDSE...

Отзывы: