Possible problem and solution:
Symptom
Possible cause(s) Corrective Action(s)
No detergent suction-units
with tanks
1. Lance nozzle is not in low
presure
2. High pressure extension
hose or high pressure hose
shorter than 25 feet.
3.Injector clogged on pump
1. Slide lance nozzle into low
pressure position (see page
13)
2. Remove high pressure
extension hose or use high
pressure hose is too long
3.Call the dealer
No detergent Suction-units
with attachable applicators
Detergent
applicator
is
clogged
1.Clean applicator with warm
water
2.Replace applicator
Unit begins to smoke
Overheated overloaded or
damaged motor
Turn off unit and call the
dealer
Possible problem and solution:
Symptom
Possible cause(s) Corrective Action(s)
Pressure washer does not
start up
1.Unit is pressurized
2.Plug is not well connected
or electric socket is faulty
3.Extension cord is too long or
wire size too small
4.Main voltage supply is too
low
5.Thermal safety switch has
tripped
1.Squeeze trigger on gun
2.Check plug, socket and
fuse
3.Remove extension cord
4.Check that main supply
voltage age is adequate
5.Switch off unit and allow
motor to cool down
Pump
does
not
reach
necessary pressure
1.Water inlet filter is clogged
2.Pump is sucking air from
hose connections
3.Nozzle is worn or not
correct size
4.Unloader is clogged or
Worn
1.Clean water inlet filter
2.Check that connections and
locking ring are properly
tightened
3.Call the dealer
4.Call the dealer
5.Call the dealer