47
The cooker must be installed and maintained by a suitably qualified gas registered
technician in accordance with current safety legislation.
Warning
: Do not use a naked flame to check for gas leaks.
Gas conversion (if available)
Your appliance is designed to be operated with LPG/NG gas. The gas burners can
be adapted to different types of gas, by replacing the corresponding injectors and
adjusting the minimum flame length suitable to the gas in use. For this purpose, the
following steps should be performed.
Changing injectors
Hob burners
•
Cut off the main gas supply and unplug the appliance from the mains electrical
supply.
•
Remove the burner caps and the adapters.
•
Use a 7 mm spanner to unscrew the injectors.
•
Replace the injector with the ones from the gas conversion kit, with the correct
diameters for the type of gas that is going to be used, according to the gas injector
table.