8
1.
Turn off gas and electricity of the cooktop. If your cooktop is hot, wait for cooling
down.
2.
For injector change, use a screwdriver whose edge is as the Figure 4.
3.
As seen in Figure 5, demount burner lid and burner of the cooktop and ensure
visibility of injector.
4.
Remove injector by turning as shown in Figure 6 wiht screwdriver and replace it with a
new one.
Figure 4 Figure 5 Figure 6
5.
After that, detach control switches of the cooktop. Make setting by turning the screw
in the middle of gas cocks with a small screwdriver in the manner shown in the
following picture. To adjust flow rate screw, use a screwdriver having suitable
dimension. For LPG, turn the screw clockwise. For natural gas, turn the screw one time
counter clockwise. At low position, length of normal flame should be 6-7 mm. For the
last control, check out whether flame is open or closed. Setting of your appliance may
differ according to the types of gas used.
Figure 7 Figure 8
GAS BREAKING SAFETY APPLIANCE (FFD)
Against putting out to be taken place as a result of liquid overflow at upper burners,
safety appliance steps in and cut gas immediately.
FFD
Figure 9
XII. NATURAL GAS / LPG