Service diagnosis
31
Domestic air conditioner
10.3.1 Thermistor or Related Abnormality
Indoor Display E1: Room temperature sensor failure
E2: Heat
●
-exchange sensor failure
Outdoor display LED1 flash 10 times
:
Defrost temperature sensor failure
LED1 flash 11 times
:
Suction temperature sensor failure
LED1 flash 12 times
:
Ambient temperature sensor failure
LED1 flash 13 times
:
Discharge temperature sensor failure
Method of The temperatures detected by the thermistors are used to determine thermistor errors
Malfunction
Detection
Malfunction When the thermistor input is more than 4.92V or less than 0.08V during compressor
.
n
o
it
a
r
e
p
o
n
o
i
s
i
c
e
D
Conditions
Note: The values vary slightly in some models
Supposed
■
Faulty connector connection
Causes
■
Faulty thermistor
●
■
Faulty PCB
Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or
●
else parts damage may be occurred.
Thermistor resistance chec
●
k method:
Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester.The
relationship between normal temperature and resistance is shown in the value of indoor thermistor.
Thermistor resistance check
Is it normal?
Yes
NO
Yes
Is it normal?
NO
Check the connector connection.
Replace the thermistor
Replace the indoor unit PCB
Correct the connection
Содержание JZ050-C1
Страница 11: ...Pinping diagrams 9 Domestic air conditioner 4 Pinping diagrams EEV EEV...
Страница 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Страница 15: ...Wiring diagrams 13 Domestic air conditioner Wiring diagrams...
Страница 57: ...Circuit diagrams 55 Domestic air conditioner 13 2Module board circuit diagram...
Страница 58: ...Sincere Forever...
Страница 59: ...Wall Mounted Type DC Inverter FREE MATCH NEW1 5P Series SERIES JZ050 C1...