Functions and control
16
Domestic air conditioner
When refrigerating, it is needed to satisfy
F-MIN-d(compressor’s Min_hz)< F<F-MAX-d(compressor’s Max_hz)
When heating, it is needed to satisfy
F-MIN-r (compressor’s Min_hz)< F<F-MAX-r (compressor’s Max_hz)
PID control :
The innital frequency Sn is determined by Pn . We can calculate Hzoutf according to the value of
Kp ,Ki ,Kd, Out_gain,Pn.Then , Fn = Sn + Hzoutf. The value of Fn is calculated in each sample time (60
seconds),and Fn is adujusted
●
according to
previous frequency of Sn and filtered output of Hzoutf.
7.1.2 The outdoor fan control (Exchange fan)
When the fan is
●
changed among every airflow speed (including stop blowing), in order to avoid the
airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds, and then
●
it can be changed to another mode (when refrigerating, the time is changed to 15 seconds).
7.1.2.1 The outdoor DC fan control
Within three minutes of compressor starting, the compressor is controled according to the ambient
temperature.
Tao
(℃)
Tao <22
℃
22
℃
< Tao <28
℃
Tao
≥
29
℃
Refrigeration/dehumidification
(09K/12K)
2nd
level /3
level
3rd
level /5th
level
5th
level /7th
level
Tao
(℃)
Tao <<10
℃
10
℃
< Tao <16
℃
Tao
≥
16
℃
Heating
7th level /7th
level
5th level /5th
level
3rd
level /3rd
level
After 3 minutes, the compressor is controled according to the ambient temperature and the frequency
of the compressor.
Refrigeration/dehumidification
frequency
(
Hz
)
09K
(
12K)
<38 Hz
(
30 Hz
)
38 Hz
(
30 Hz
)
-52 Hz
(
60 Hz
)
≥
52 Hz
(
60 Hz
)
Tao
(℃)
≤
22
2nd level
3rd level
5 th level
22-28
3rd level
5 th level
7 th level
≥
28
7 th level
Heating frequency
(
Hz
)
(09K/12K)
<51 Hz
51-70 Hz
≥
70 Hz
Tao
(℃)
≤
10
2nd level
3rd level
5 th level
10
●
-17
3rd level
5 th level
7 th level
≥
17
2nd level
7.1.3 The control of the outdoor Electronic expansion valve (EEV)
In cooling mode, the EEV
●
opening range is 120~480 steps. The EEV opening is 120 steps when unit is
off.
In heating mode, the EEV opening range is 60~480 steps. The EEV opening is 60 steps when unit is
off.
Содержание JZ050-C1
Страница 11: ...Pinping diagrams 9 Domestic air conditioner 4 Pinping diagrams EEV EEV...
Страница 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Страница 15: ...Wiring diagrams 13 Domestic air conditioner Wiring diagrams...
Страница 57: ...Circuit diagrams 55 Domestic air conditioner 13 2Module board circuit diagram...
Страница 58: ...Sincere Forever...
Страница 59: ...Wall Mounted Type DC Inverter FREE MATCH NEW1 5P Series SERIES JZ050 C1...