Measurement Report Template | Creating and editing a template

 

6

 

80

HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018

Form field

Meaning and application

Tolerance general state

The overall status of all of the tolerances that have
been inserted into the feature are inserted (e.g.,

Passed

, if all of the individual tolerances are good).

Tolerance type

The tolerance types applied to the feature are
inserted.

Tolerance state

The statuses of the tolerances applied to the
feature are inserted.

Nom. dimension / Toler-

ance zone

The nominal dimension or the value of the toler-
ance zone of a tolerance applying to a feature is
inserted.

Actual value

The actual dimension of a tolerance applied to the
feature is inserted.

Deviation

The difference between nominal dimension and
actual dimension is inserted.

Lower tolerance

The lower tolerance limit of a tolerance applied to
the feature is inserted.

Upper tolerance

The upper tolerance of a tolerance applied to the
feature is inserted.

Lower limit

The lower limit of a tolerance applied to the feature
is inserted.

Upper limit

The upper limit of a tolerance applied to the feature
is inserted.

Trend [-/+++]

The trend of the deviation is inserted.

The tolerance zone is divided into seven segments.
The result is assigned to the corresponding
segment. The corresponding segment is shown as
a trend:

Segment -3: 

---

Segment -2: 

--

Segment -1: 

-

Segment 0: 

.

S1: 

+

S2: 

++

S3: 

+++

Reference, bonus

The reference feature of a tolerance applied to the
feature is inserted.

If a material requirement is being used, the exist-
ing tolerance bonus is inserted.

Содержание QUADRA-CHEK 2000 Demo

Страница 1: ...QUADRA CHEK 2000 Demo User s Manual Evaluation Unit English en 06 2018...

Страница 2: ...00 Demo User s Manual 06 2018 Contents 1 Fundamentals 7 2 Software Installation 11 3 Basic Operation 17 4 Software Configuration 41 5 Quick Start 47 6 Measurement Report Template 69 7 ScreenshotClient...

Страница 3: ...features 8 1 3 Intended use 9 1 4 Improper use 9 1 5 Demo software for demonstration of the device functions 9 1 6 Notes on reading the documentation 9 1 7 Symbols and fonts used for marking text 10 2...

Страница 4: ...and logout 24 3 5 1 User login 24 3 5 2 User logout 24 3 6 Setting the language 25 3 7 User interface 25 3 7 1 User interface after Startup 25 3 7 2 Main menu of the user interface 26 3 7 3 Measure me...

Страница 5: ...n OED sensor 49 5 2 2 Displaying and editing the measurement results 57 5 2 3 Creating a measurement report 64 6 Measurement Report Template 69 6 1 Overview 70 6 2 Creating and editing a template 71 6...

Страница 6: ...nnecting ScreenshotClient with the demo software 85 7 5 Connecting ScreenshotClient with the unit 86 7 6 Configuring ScreenshotClient for taking screenshots 86 7 6 1 Configuring the storage location a...

Страница 7: ...1 Fundamentals...

Страница 8: ...iar with try out or present the functions of the device 1 2 2 Demo software features Because of the missing hardware environment the range of features of the demo software does not correspond to the c...

Страница 9: ...r use QUADRA CHEK 2000 Demo is not intended for any use other than the intended use Any use for other purposes is prohibited specifically For productive purposes in production systems As part of produ...

Страница 10: ...instructions the following symbols and fonts are used for marking text Depiction Meaning Identifies an action and the result of this action Example Tap OK The message is closed Identifies an item of a...

Страница 11: ...2 Software Installation...

Страница 12: ...tory of the appropriate product If you do not have access rights to the Portal s Software folder you can request the access rights from your HEIDENHAIN contact person Download the latest version of QU...

Страница 13: ...step accept the terms of the license Tap Next In the Select Destination Location installation step the installation wizard suggests a storage location We recommend retaining the suggested storage loc...

Страница 14: ...eenshot Utility Tap Next In the Select Start Menu Folder installation step select the storage location at which you want to create the start menu folder Tap Next In the Select Additional Tasks install...

Страница 15: ...ft Windows Start All programs HEIDENHAIN QUADRA CHEK 2000 Demo Tap Uninstall The uninstallation wizard opens To confirm unistallation tap Ja Unistallation starts and the progress bar indicates the sta...

Страница 16: ......

Страница 17: ...3 Basic Operation...

Страница 18: ...ments and basic functions of QUADRA CHEK 2000 Demo 3 2 Using the touchscreen and input devices 3 2 1 Touchscreen and input devices The operating elements on the user interface from QUADRA CHEK 2000 De...

Страница 19: ...the touchscreen or the mouse are identified by the following symbols Operation using the touchscreen Operation using the mouse The following overview describes the different gestures for operating the...

Страница 20: ...rting point of the motion is defined The actions initiated by dragging include Scrolling through lists and texts Opening the Details dialog in the Inspector Two finger drag Refers to the movement of t...

Страница 21: ...displayed The entry cannot be concluded in this case To apply the values confirm the entry with RET The values are displayed The screen keyboard disappears Input fields with plus and minus buttons To...

Страница 22: ...opens The active entry is highlighted in green Tap the desired entry The selected entry is applied Undo With this button you can undo the last action Processes that have already been concluded cannot...

Страница 23: ...soft Windows Start All programs HEIDENHAIN QUADRA CHEK 2000 Demo Two executable files with different modes of appearance are available QUADRA CHEK 2000 Demostarts within a Microsoft Windows window QUA...

Страница 24: ...be logged in to the product at a time The logged in user is displayed Before a new user can log in the logged in user has to log out The product provides various authorization levels that grant the u...

Страница 25: ...s indicated by a national flag in the Language drop down list Select the flag for the desired language in the Language drop down list The user interface is displayed in the selected language 3 7 User...

Страница 26: ...activated software options Operating element Function 0 Message Display of an overview of all messages as well as the number of messages that have not been closed Measure Manual measurement constructi...

Страница 27: ...perating element Function Settings Settings of the unit such as setting up users configuring sensors and updating the firmware Further information Settings menu Page 34 Switch off Shutdown of the oper...

Страница 28: ...visible if the software option is active 3 The workspace displays for example the position display or the input area for constructing and defining features 4 The Inspector contains the quick access m...

Страница 29: ...l measuring Defining Measure Define Operating elements of the sensor palette The operating elements of the sensor palette are only available if software options are active If one software option is ac...

Страница 30: ...Distance Angle Blob Zero point Alignment Reference plane Zero point Alignment Ref plane The Reference plane operat ing element is only available if the Z axis is active Operating elements of the OED...

Страница 31: ...nd creating the measurement reports appears Short description 1 2 3 Figure 6 Measurement report menu 1 List of default templates 2 Preview of the selected template 3 Display of information on the sele...

Страница 32: ...ivation Tap File management in the main menu The user interface for file management is displayed Short description 1 2 Figure 7 File management menu 1 List of available storage locations 2 List of fol...

Страница 33: ...for user login and logout is displayed Short description 1 2 Figure 8 User login menu 1 Display of the logged in user 2 User login The User login menu shows the logged in user in the column on the lef...

Страница 34: ...is displayed Short description 1 2 Figure 9 Settings menu 1 List of setting options 2 List of setting parameters The Settings menu shows all options for configuring the product With the setting param...

Страница 35: ...ff and puts the operating system into energy saving mode Cleaning mode Switches the screen off the operating system continues unchanged Further information QUADRA CHEK 2000 Demo startup and shut down...

Страница 36: ...nts of the manual measuring function for adjusting the features view in the case of reduced workspace Display annotations Settings Zoom functions Regardless of the size of the workspace the available...

Страница 37: ...ed To adjust the settings of the quick access menu tap the quick access menu Position preview The position preview is only available in the manual measuring function The current axis positions are dis...

Страница 38: ...ymbol Each feature contains details on the measurement results as well as selectable tolerances To display the measured values and adjust the tolerances drag a feature into the workspace The detail wi...

Страница 39: ...g the program control in the workspace Opening and saving a coordinate system Deleting selected features or all features from the feature list Feature selection Multiple selection of features of the s...

Страница 40: ...ool Functions and characteristics Crosshair Crosshair Manual acquisition of single measuring points No automatic acquisition of light to dark transitions OED OED Active measuring tool Acquisition of l...

Страница 41: ...4 Software Configuration...

Страница 42: ...ctions described below Further information Basic Operation Page 17 Before you can use QUADRA CHEK 2000 Demo correctly after successful installation you need to configure QUADRA CHEK 2000 Demo This cha...

Страница 43: ...QUADRA CHEK 2000 Demo You must upload the license file in order to enable the available software options Tap Settings in the main menu The unit s settings appear Figure 11 Settings menu Tap Service Op...

Страница 44: ...cessed by QUADRA CHEK 2000 Demo Move to the temporary storage folder For example copy the configuration file DemoBackup mcc to the following folders C HEIDENHAIN product name Metrology ProductsMGE5 pr...

Страница 45: ...pload the configuration file DemoBackup mcc Tap Settings in the main menu The product settings are displayed Figure 12 Settings menu Tap Service Open in the sequence Back up and restore Restore settin...

Страница 46: ...n list The user interface is displayed in the selected language 4 6 Selecting the product version optional QUADRA CHEK 2000 is available in different versions These versions differ in their interfaces...

Страница 47: ...5 Quick Start...

Страница 48: ...object and measuring the features through to creating the measurement report For a detailed description of the individual activities please refer to the Measuring Measurement evaluation and Measuremen...

Страница 49: ...ith an OED sensor various measuring tools are available to you for the acquisition of measuring points Further information Measuring tools Page 40 Aligning the measured object Before you can evaluate...

Страница 50: ...s menu select the magnification that is set on the measuring machine Select Alignment in the geometry palette Select Auto OED in the tool palette Cross over the reference edge multiple times with the...

Страница 51: ...times with the OED sensor A new feature is displayed in the feature list of the Inspector A new measuring point is added for each pass over the reference edge Distribute the measuring points along the...

Страница 52: ...ry palette Select the Alignment and Line features in the Inspector or in the features view The selected features are displayed in green A new feature with the selected geometry is displayed Tap Finish...

Страница 53: ...EK 2000 Demo User s Manual 06 2018 53 Measuring features To measure features you can use the geometries of the geometry palette Figure 17 Examples of measuring a 2 D demo part The section below descri...

Страница 54: ...n the geometry palette Select OED in the tool palette Cross over the edge of the circle with the OED sensor multiple times The unit records the measuring point in the clipboard To confirm the measurin...

Страница 55: ...Quick Start Conducting a measurement 5 HEIDENHAIN QUADRA CHEK 2000 Demo User s Manual 06 2018 55 Figure 18 Circle feature in the feature list with Measurement result preview...

Страница 56: ...in any sequence Select Slot in the geometry palette Select Auto OED in the tool palette Cross over the edge of the slot multiple times with the OED sensor A new feature is displayed in the feature li...

Страница 57: ...A new feature is displayed in the feature list A new measuring point is added for each pass over the reference edge Distribute the measuring points as evenly as possible along the contour of the feat...

Страница 58: ...sed for calculating the feature 6 Fitting algorithm used for calculating the feature depends on the geometry and the number of measuring points 7 Informational text field if an annotation is active th...

Страница 59: ...ve a feature e g a Circle from the features list into the workspace The Details dialog appears with the Overview tab selected The fitting algorithm used is shown in the Fitting algorithm drop down lis...

Страница 60: ...the Details dialog Drag the Slot feature from the feature list into the workspace The Details dialog appears with the Overview tab selected The geometry type of the feature is displayed In the New ty...

Страница 61: ...3 Status of the tolerance Active and within the tolerance or active and outside the tolerance In the Tolerances tab you can define the geometrical tolerancing of a feature The tolerances are grouped...

Страница 62: ...erance input field and enter 0 1 Confirm entry with RET Tap the Lower tolerance input field and enter 0 1 Confirm entry with RET The nominal value is shown in red if it is out of tolerance The nominal...

Страница 63: ...can add an annotation to every feature in the features view e g measurement information or informational texts 1 2 3 4 Figure 26 Operating elements for annotations and feature with annotations 1 Edit...

Страница 64: ...ement report in the main menu The user interface for editing the measurement reports appears Select the Standard template The preview of the selected template is displayed Tap Create to create the mea...

Страница 65: ...erator Function Is Only features of the selected geometry type are shown Type Is not Only features of the non selected geometry type are shown Equal Only features of the specified size are shown Great...

Страница 66: ...ing document settings Tap the Document menu Select the YYYY MM DD hh mm date and time format in the Date and time format drop down list Tap the Preview menu The preview of the measurement report is di...

Страница 67: ...measurement report In the File management main menu you can open the saved report Tap File management in the main menu Select the Internal Reports storage location Select the desired Demo1 pdf file A...

Страница 68: ......

Страница 69: ...6 Measurement Report Template...

Страница 70: ...can create detailed reports for your measuring tasks You can document one or more measured features in a measurement report The measurement reports can be printed exported and saved For the creation o...

Страница 71: ...reating and editing a template With the editor you can create your own custom measurement report templates Opening a new template with the editor Editing the default settings for the measurement repor...

Страница 72: ...r Tap Measurement report in the main menu Maximize the window of the software on the computer screen The Add button appears in the list of templates Figure 31 Measurement report menu with the list of...

Страница 73: ...elect the desired unit of measurement in the Unit for angular values drop down list Select the desired format in the Date and time format drop down list To reduce or increase the Grid size tap or The...

Страница 74: ...ader of a measurement report template 1 The different sections of the template can be edited in the editor menu 2 The form fields for the template are adjustable 3 The list shows the form fields that...

Страница 75: ...ut field tap anywhere outside the input field Variable text Variable text is inserted You can type the variable text into the template When creating the measurement report you can overwrite the text a...

Страница 76: ...eader parameter is active in the Default settings menu 4 3 2 1 Figure 34 Report header of a measurement report template 1 The different sections of the template can be edited in the editor menu 2 The...

Страница 77: ...riable text Variable text is inserted You can type the variable text into the template When creating the measurement report you can overwrite the text as needed Logo A logo is inserted Tap the Logo fo...

Страница 78: ...The change to the form field is applied 6 2 5 Defining data for a measurement report Tap Data 4 3 2 1 Figure 35 The data table of a measurement report template 1 The different sections of the templat...

Страница 79: ...oordinate Cartesian is inserted Z The Z coordinate Cartesian is inserted Coordinate system The coordinate system that is used for the feature is inserted r The radial coordinate polar is inserted The...

Страница 80: ...d to the feature is inserted Deviation The difference between nominal dimension and actual dimension is inserted Lower tolerance The lower tolerance limit of a tolerance applied to the feature is inse...

Страница 81: ...area are marked red The changes to the data table are applied 6 2 6 Saving a template The templates are saved in the XMT data format To save the template tap Save as The Save as dialog appears Select...

Страница 82: ...er Reports custom_templates Copy the file to a network drive or USB mass storage device Import the file into the unit Tap File management in the main menu On the USB mass storage device or network dri...

Страница 83: ...7 ScreenshotClient...

Страница 84: ...shotClient you can take screenshots of the active screen of the demo software or the unit from a computer Before taking a screenshot select the desired user interface language as well as the file name...

Страница 85: ...ient with the demo software or with the unit 7 4 Connecting ScreenshotClient with the demo software Before establishing a connection with ScreenshotClient first start the demo software or switch on th...

Страница 86: ...ction with the unit is established The status message is updated The Identifier and Language input fields become active 7 6 Configuring ScreenshotClient for taking screenshots Once you have started Sc...

Страница 87: ...e screenshots Screenshots are always created in the language that you have selected in ScreenshotClient Screenshots in the desired user interface language To take screenshots in a desired user interfa...

Страница 88: ...Tap Snapshot The screenshot is created and saved to the configured storage location The screenshot is saved in the format file name _ language code _ YYYYMMDDhhmmss e g screenshot_en_20170125114100 T...

Страница 89: ...porting 66 Filtering features 65 Information on the measuring task 66 Menu 31 Opening 67 page header 74 Report header 76 saving a template 81 Selecting data 78 Template and features 64 Measurement rep...

Страница 90: ...sed for marking text 10 T Tapping 19 Touchscreen Operation 18 Two finger drag 20 U Use Improper 9 Intended 9 User Login 24 Logout 24 User login 24 User interface After startup 25 File management menu...

Страница 91: ...w 55 Image 19 Slot feature in the feature list with Measurement result preview 56 Image 20 Blob feature in the feature list with Measurement result preview 57 Image 21 Overview tab in the Details dial...

Страница 92: ...8669 31 3104 E mail service ms support heidenhain de NC support 49 8669 31 3101 E mail service nc support heidenhain de NC programming 49 8669 31 3103 E mail service nc pgm heidenhain de PLC programm...

Отзывы: