HEIDENHAIN ECI 1119 Скачать руководство пользователя страница 7

Electrical connection – pin layout

Pin layout

8-pin coupling or
flange socket M12

15-pin PCB
connector

Voltage supply

Position values

Other signals

 1) 

M12

8

2

5

1

3

4

7

6

/

/

13

11

14

12

7

8

9

10

5

6

U

P

Sensor 

U

P

0 V

Sensor 

0 V

DATA

DATA

CLOCK

CLOCK

T+

 2) 

T-

 2) 

Brown/

Green

Blue

White/

Green

White

Gray

Pink

Violet

Yellow

Brown

Green

1)

Only with adapter cables inside the motor

2)

Connections for external temperature sensor; evaluation optimized for KTY 84-130 (see 

Temperature measurement in motors

 in the

Encoders for Servo Drives

 catalog)

Cable shield

 connected to housing; 

Up

 = Power supply

 

Sensor:

 The sensor line is connected in the encoder with the corresponding power line

 

Vacant pins or wires must not be used!

 

Note for safety-oriented applications:

 Only HEIDENHAIN cables complete with connectors are qualified for use. Exchange connectors or

modify cables only after consultation with HEIDENHAIN Traunreut.

This Product Information supersedes all previous editions, which thereby become invalid.
The basis for ordering from HEIDENHAIN is always the Product Information valid when the
contract is made.

Related documents:

 Adhere to the information in the following documents to ensure the

correct and intended operation of the encoder:

Catalog 

Encoders for Servo Drives 

208922-xx

Mounting Instructions: 

ECI 1119, EQI 1131

 1082414-xx

Technical Information: 

Safety-Related Position Measuring Systems 

596632

For implementation in a safe control or inverter: Specification: 533095 and

supplementary catalog of measures (SIL 3, PL e) 

1000344

1087103 · 00 · C · 02 · 4/2014 · PDF

Содержание ECI 1119

Страница 1: ...Product Information ECI 1119 EQI 1131 Absolute Rotary Encoders without Integral Bearings Suited for safety related applications up to SIL 3 when coupled with additional measures 4 2014...

Страница 2: ...LA1 1KA 5 Flange surface ECI EQI ensure full surface contact 6 ECN EQN coupling surface 7 Maximum permissible deviation between shaft and coupling surfaces Compensation of mounting tolerances and ther...

Страница 3: ...age supply 3 6 V DC to 14 V Power consumption 4 maximum At 3 6 V 650 mW At 14 V 700 mW At 3 6 V 750 mW at 14 V 850 mW Current consumption typical At 5 V 95 mA without load At 5 V 115 mA without load S...

Страница 4: ...annot be reused Unused screws are not storable indefinitely The minimum shelf life is 2 years storage at 30 C and 65 relative humidity The expiration date is printed on the package ECI 1119 EQI 1131 S...

Страница 5: ...hold of the warning bit for excessive temperature and can be individually adjusted A device specific default value is saved here when the encoder is shipped The temperature measured by the internal te...

Страница 6: ...de bit error rate as per specification 533095 PUR connecting cable PUR 6 mm 4 0 4 mm 4 0 34 mm AP 0 34 mm2 Complete with M12 connector female and M12 coupling male both with 8 pins ID 368330 xx Comple...

Страница 7: ...pins or wires must not be used Note for safety oriented applications Only HEIDENHAIN cables complete with connectors are qualified for use Exchange connectors or modify cables only after consultation...

Отзывы: