Electrical connection – cables

Cables

Cables inside the motor housing 

Ø

 4.5 mm;

Complete

 with PCB connector (15-pin) and M12

flange socket (male), 8-pin; wires for temperature
sensor

TPE 10

×

0.14 mm

 2 

 1) 

ID 746795-xx

Complete 

with PCB connector (15-pin) and M12

flange socket (male) 8-pin

TPE 8

×

0.14 mm

 2 

 1) 

ID 804201-xx

1)

Single wires with braided sleeving; shield must be connected on the motor

Note for safety-related applications: 

Provide bit error rate as per specification 533095!

 

PUR connecting cable PUR

 

Ø

 6 mm; [(4

×

0.4 mm²) + (4

×

0.34 mm²)]; A

P

 = 0.34 mm

 2 

Complete

 with M12 connector (female) and M12

coupling (male), both with 8 pins

ID 368330-xx

Complete

 with 8-pin M12 connector (female) and

15-pin D-sub connector (female)

ID 533627-xx

Complete

 with M12 connector (female), 8-pin and

sub-D connector (male), 15-pin

ID 524599-xx

With one

 M12 connector (female), 8-pin

ID 634265-xx

 1) 

A

P

:

Cross section of power supply lines

1)

Connecting element must be suitable for the maximum clock frequency used

 

Note for safety-related applications: 

Provide bit error rate as per specification 533095!

Содержание ECI 1119

Страница 1: ...Product Information ECI 1119 EQI 1131 Absolute Rotary Encoders without Integral Bearings Suited for safety related applications up to SIL 3 when coupled with additional measures 4 2014...

Страница 2: ...LA1 1KA 5 Flange surface ECI EQI ensure full surface contact 6 ECN EQN coupling surface 7 Maximum permissible deviation between shaft and coupling surfaces Compensation of mounting tolerances and ther...

Страница 3: ...age supply 3 6 V DC to 14 V Power consumption 4 maximum At 3 6 V 650 mW At 14 V 700 mW At 3 6 V 750 mW at 14 V 850 mW Current consumption typical At 5 V 95 mA without load At 5 V 115 mA without load S...

Страница 4: ...annot be reused Unused screws are not storable indefinitely The minimum shelf life is 2 years storage at 30 C and 65 relative humidity The expiration date is printed on the package ECI 1119 EQI 1131 S...

Страница 5: ...hold of the warning bit for excessive temperature and can be individually adjusted A device specific default value is saved here when the encoder is shipped The temperature measured by the internal te...

Страница 6: ...de bit error rate as per specification 533095 PUR connecting cable PUR 6 mm 4 0 4 mm 4 0 34 mm AP 0 34 mm2 Complete with M12 connector female and M12 coupling male both with 8 pins ID 368330 xx Comple...

Страница 7: ...pins or wires must not be used Note for safety oriented applications Only HEIDENHAIN cables complete with connectors are qualified for use Exchange connectors or modify cables only after consultation...

Отзывы: