IMPORTANT NOTICE: If the fan is restarted following a power failure, or accidental switching off, be sure to verify
that the fan is running correctly. If the flapper valve doesnot close properly, or is missing, the deflation of the unit
may cause the fan to spin in the opposite direction when restarted. If this happens, the blower will not inflate the
unit properly.
10577 Rocket Blvd., Suite C, Orlando, FL 32824 Toll Free: 800-354-1183
Fax: 407-563-5493
Operating Instructions:
Tropical Slip n Slide
Page 2
Maintenance and Inspection:
1.
The unit can be easily cleaned with a cloth or light brush. Use a vinyl cleaner and rinse thoroughly to remove detergent before
storing.
2.
Do not pack the unit when wet. If this is unavoidable lay the unit out to dry at the earliest opportunity.
3.
The unit should be inspected regularly for damage . If there is evidence of tearing at the anchor points or vinyl panels, the unit
should not be used until the repair has been completed.
Repairs:
1.
To repair small tears up to 12 "use"Single Patch Method "as follows.
2.
Cut an oval or round vinyl patch approximately 4" larger than the cut.
3.
Clean the area around the tear using rubbing alcohol.
4.
Apply HH-66vinyl glue on the patch and on the surface of the inflatable.
5.
Allow the manufactures recommended drying time before applying the patch to the inflatable as indicated on the label on the
container.
6.
Place the patch covering the cut area and apply pressure for 1 minute. Refer to the glue manufactures label for the recommended
time for glue to dry once the patch is applied.
7.
If the "Single Patch Method" is not a viable option use Tear Aid for a temporary repair until you can apply the "Single Patch
Method" or send the unit to a repair facility .
Daily Checklist:
Ensure maximum winds are less than the manufactures recommended wind speed requirement for unit.
Ensure temperatures are greater than 40 F.
Ensure Blower is hook to a GFCI ( Ground Fault Circuit Interrupter) .
Ensure there are no obstructions in the blowers and their inflation tubes.
Ensure unit is properly Inflated.
Ensure all tether points are secure. Ensure all deflation zippers and flaps are closed.
Walk around the unit and inspect seams and search for wear damage.
Water hose installation:
1.
A Soaker Sleeve as been installed on the slide.
2.
Water is supplied for this ride from a standard garden hose, the garden hose is placed into the soaker sleeve attached to the
netting and secured by a Velcro Strap.