Selection guide
General recommendations for
HEATSTRIP
®
Classic with remote:
•
Ideal mounting height: 2.3m to 2.5m. Maximum is 2.7m in a fully protected/enclosed outdoor environ-
ment.
•
Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)
•
Based on the radiant footprint of the previous page, for a protected outdoor area, a minimum of
500W/m
2
is required. For indoor spot heating, a minimum heating capacity of 400W/m
2
is recom-
mended.
The table below outlines the coverage of each
HEATSTRIP
®
Classic with remote
model based on 3 differ-
ent scenarios with direct overhead mounting. For example, for an outdoor area that is protected from pre-
vailing winds by walls, café blinds etc, Model THH2400AR will cover 4.8m
2
and Model THH3200AR will cover
6.4m
2
For angled wall mounting applications, the coverage is reduced by up to 40%.