8
Selection guide
General recommendations for
HEATSTRIP
®
Elegance:
•
Ideal mounting height: 2.3m to 2.5m. Maximum is 2.7m in a fully protected/enclosed outdoor environment.
•
Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table)
•
Minimum recommended heating capacity for various installations are: 400W/m
2
for indoor spot heating; 500W/m
2
for protected outdoor areas, and 600W/m
2
for exposed outdoor areas. To ensure the HEATSTRIP
®
Elegance pro-
vides satisfactory performance, Thermofilm strongly recommends using conservative coverage areas when speci-
fying how many heaters are required for each installation.
The table below outlines the
maximum
coverage of each
HEATSTRIP
®
Elegance
model based on 2 different scenarios
with direct overhead mounting at minimum installation height. For example, for an outdoor area that is protected from pre-
vailing winds by walls, café blinds etc, Model THE2400EUR will cover a
maximum
of 4.8m
2
and Model THE3200EUR will
cover a
maximum
of 6.4m
2
.
For angled wall mounting applications, the coverage is reduced by up to 40%.
MODEL
INDOOR PROTECTED (m
2
)
OUTDOOR ENCLOSED (m
2
)
OUTDOOR EXPOSED (m
2
)
THE2400EUR
6
4.8
4
THE3200EUR
8
6.4
5.3
Содержание ELEGANCE
Страница 1: ...1 HEATSTRIP ELEGANCE with Remote THE R Range Superior Technology Superior Style Product Manual ...
Страница 21: ...21 HEATSTRIP ELEGANCE with Remote THE R Range Superior Technology Superior Style Product Manual ...
Страница 41: ...41 HEATSTRIP ELEGANCE with Remote EUROPE Le radiateur design Product Manual ...