background image

 

11  

 

DETAIL A

A

B

A

B

20 MINIMUM

175 MAXIMUM

BEAM or POLE

BEAM or POLE

SCREWS
(NOT INCLUDED)

SCREWS
(NOT INCLUDED)

BEAM or POLE

SCREWS
(NOT INCLUDED)

STANDARD MOUNTING BRACKET

TRANSVERSE MOUNTED

WIDE CENTERED MOUNT

NARROW CENTERED MOUNT

OFFSET MOUNT

BEAM or POLE

HEATER

POLE/BEAM MOUNTING BRACKET

HEATER

POLE/BEAM MOUNTING BRACKET

HEATER

POLE/BEAM MOUNTING BRACKET

HEATER

POLE/BEAM MOUNTING BRACKET

20 MINIMUM

POLE

NUT & BOLT (NOT INCLUDED)

NARROW CENTERED MOUNT

HEATER

POLE/BEAM MOUNTING BRACKET

70mm Maximum

4

2m

m

 M

A

X

.

5mm HARDWARE

PART B

14

160

10

21.

6

50

25

40

20

M

N

U

T

Ø6

20

25

10

1.

6

165

13

1.

6

25

50

M5 NUT

190

Standard Mounting Brackets 
 

The HEATSTRIP Indoor comes with a pair of standard mounting brackets. These brackets allow direct ceiling mount. 
 
The brackets need to be mounted onto a secure frame or ceiling with a minimum distance between the two brackets. The 
minimum distance (“B”) for each model is listed in the table below. 
 
When completing the installation, ensure all screws are tight and unit is secure. 
 

PART No 

PACKAGED  

DIMENSIONS (mm) 

WEIGHT 

(kg) 

MATERIALS 

ZBRAK-92 

200 x 50 x 50 

0.5 

MILD STEEL POWDER-

COATED WHITE 

Standard Mounting Bracket 

MODEL 

“B” 

MINIMUM DISTANCE (mm) 

THS1200AEU 

500 

THS2400AEU 

1000 

Содержание Design THH Series

Страница 1: ...OPERATION INSTALLATION AND MAINTENANCE MANUAL The heater that is a design feature HEATSTRIP Indoor EUROPE ...

Страница 2: ...nts 8 Installation location 9 Mounting options 10 Standard mounting brackets 11 Angle mounting brackets 12 Flush mount enclosure 13 End to end mounting bracket 14 Suspension mount bracket 15 T Bar mount 16 Wall controller with remote 17 Wall controller installation guide 18 Safety Maintenance 19 Warranty terms conditions 20 ...

Страница 3: ...t up to 3 5m X X Exposed outdoor area X X Indoor open area warehouse factory production areas sports facilities Indoor spot heating above tables assembly areas There are 3 different ranges of products within the Heatstrip product category Each has a different temperature specification making them ideal for different applications Below is a list of some common applications to assist with the select...

Страница 4: ...t environment Design Flexibility to Meet BCA requirements 4 different models and multiple mounting options within the range allows for the design of innovative heating systems to meet stringent BCA requirements Suitable for Multiple Applications commercial residential HEATSTRIP Indoor can be designed to provide comfort heating for a single room or a large stadium and either a large group or a sing...

Страница 5: ...2KW 2 4 KW Manual heat charge control Single stage heat output and no room temperature control POWER 230 240 Volts Nominal at 50 60 Hertz Single Phase CONNECTION 3 Core Cable 1 5mm2 APPROVALS AUSTRALIA NZ MOUNTING HEIGHT MINIMUM RECOMMENDED MAXIMUM 2 1 m 2 3 m to 2 7 m 3 0 m For higher ceiling heights units can be lowered using optional bracket kits or refer to the Heatstrip Max range MOUNTING OPT...

Страница 6: ...les lounges and workstations Often it ism ore practical and efficient to spot heat these areas Spot heating will help reduce the initial capital cost as well as the ongoing running costs Spot heating will allow also the area to be zoned meaning heating on the areas that being used such as tables in restaurants The top table shows a comparison between spot heating over a table or heating an entire ...

Страница 7: ...eg above a table seating area etc The below table outlines the coverage of each HEATSTRIP Indoor model in m2 based on 2 different scenarios For example for an indoor area that is protected Model THS1200AEU will cover 8m2 and Model THS2400AEU will cover 16m2 MODEL INDOOR INSULATED m2 INDOOR PROTECTED m2 THS1200AEU 12 8 THS2400AEU 24 16 The above is a guide only and may vary depending on the individ...

Страница 8: ...uce the height of the heater to 2 3m 3 0m This will increase the effectiveness of your HEATSTRIP Refer to the Mounting Accessory section for more information Electrical connections GPO s should not be located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the units If the heater is to be mounted on an incline eg vaulted...

Страница 9: ...9 Installation Location the below diagrams confirm the minimum recommended clearances Ceiling Installation Angled Wall Installation Angled ...

Страница 10: ...lable refer to below diagrams The HEATSTRIP Indoor can be mounted directly to the ceiling angled downwards on a wall fitted flush with the ceiling suspended on chains or mounted end to end Refer to the following pages for more detailed information on each mounting option T BAR MOUNT STANDARD MOUNTING BRACKETS INCLUDED IN BOX FLUSH MOUNT ENCLOSURE END TO END MOUNTING BRACKET SUSPENSION MOUNT BRACKE...

Страница 11: ...cure frame or ceiling with a minimum distance between the two brackets The minimum distance B for each model is listed in the table below When completing the installation ensure all screws are tight and unit is secure PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS ZBRAK 92 200 x 50 x 50 0 5 MILD STEEL POWDER COATED WHITE Standard Mounting Bracket MODEL B MINIMUM DISTANCE mm THS1200AEU 500 THS2...

Страница 12: ...r the wall to bring the effective heat closer to where it is needed The angle of the bracket is preset to 45o When installing ensure that the minimum distances are maintained Screws are not provided PART No PACKAGED DIMENSIONS mm WEIGHT kg MATERIALS THSAC 020 200 x 200 x 50 0 5 MILD STEEL POWDER COATED WHITE Angle Mounting Bracket ...

Страница 13: ... ideal mounting height is 2 1 2 7m Maxi mum mounting heights should be strictly followed otherwise the performance of the units may be reduced The facia is made from white powdercoated mild steel SUITABLE FOR MODELS PART No HOLE CUTOUT DIMENSIONS mm OVERALL DIMENSIONS mm WEIGHT kg THS1200AEU THSAC 026 1020 x 325 1040 x 345 x 100 4 THS2400AEU THSAC 028 1930 x 325 1950 x 345 x 100 5 HEATER FLUSH MOU...

Страница 14: ... maximum heat performance and aesthetic appeal This is ideal for applications such as long rows of tables and assembly lines where a constant heat coverage is required The bracket allows for a 50mm gap between units and an opening for the power connection As per the dia gram below units should be mounted with the power leads together The end to end bracket can be used with the standard ceiling wal...

Страница 15: ...unt bracket provides a cheap easy and effective option for lowering the HEATSTRIP Indoor from high ceilings If the ceiling height is more than 2 7m is an enclosed outdoor environment It is recommended to lower the heaters to an ideal mounting height of 2 1m 2 7m The bracket is designed to be used with chains or wires There can be multiple chain wire arrangement options as per the below diagram Not...

Страница 16: ...ing heights should be strictly followed otherwise the performance of the units may be reduced The facia of the enclosure is manufactured from mild steel powdercoated white in a durable finish SUITABLE FOR MODELS PART No HOLE CUTOUT DIMENSIONS mm OVERALL DIMENSIONS mm WEIGHT kg THS800AEU THSAC 023 1080 x 280 1090 x 290 x 100 4 THS1200AEU THSAC 024 1080 x 280 1090 x 290 x 100 4 HEATER T BAR MOUNT CE...

Страница 17: ...ght will show which time setting is selected The timer will start the heater and automatically turn it off at the preselected time Safety The TT MTR controller must be installed in a dry location It is not suitable for installation where rain or water could affect the unit Ensure the connections are properly connected This appliance is not intended for use by persons including children with reduce...

Страница 18: ...18 Wall Controller Installation Guide GANG BOX TT MTR WALL SCREW ...

Страница 19: ...to be installed as per the installation instructions paying special attention to the minimum clearances The heater needs to be mounted on a rigid bracket or fixing The heater must not be mounted immediately below or in front of a socket outlet In case of a heater fault or damaged supply lead the appliance should be returned to the point of purchase for return to Cook Heat B V for repair Maintenanc...

Страница 20: ...red by Cook Heat B V to destination Discolouration of the surface may occur after a period of time this does not constitute a warrantable event Twisting and bending of the heaters may occur this does not constitute a warrantable event No products or components will be supplied in advance of an examination of the faulty product or components by Cook Heat B V or an authorized representative of Cook ...

Отзывы: