Installation Instructions and Owner’s Manual

Unvented Natural Gas Vent Free Room Heaters

Product Features

Figure 1

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion 
Sensor (ODS) safety shut off system. The ODS/pilot 
shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM / BATTERY INSTALLATION

– The heater is equipped with an electronic manual 
ignitor. This system requires no matches, or other 
source to light heater, but does require one AA battery 
to operate ignitor. 

(AA Battery included)

.

To install or replace battery unscrew the ignitor cap 
(red button), insert battery positive (+) terminal up 
and replace cap.

(AA Battery included)

THERMOSTATIC CONTROL

These heaters have a control valve with a thermostat 
sensing bulb. This results in the greatest heater comfort 
and may result in lower bills.

BLOWER FAN CONTROL SWITCH OPERATION

On models equipped with an electrical blower. The blower 
switch has three positions: MANUAL, OFF and AUTO. In 
AUTO, the blower will turn on and off as the heater cycles 
on and off. On MANUAL, the blower will run continuously. 
To turn blower off, use the OFF position.

LOCAL CODES

Install and use heater with care. 

Installation must conform to local codes or in the ab-
sences of local codes, use the latest edition of National 
Fuel Gas Code ANSI Z223.1/NFPA 54.

UNPACKING

1.  Remove heater from carton.

2.  Remove all protective packaging applied to 

heater for shipment.

3.  Check heater for any shipping damage. If 

heater is damaged, promptly inform dealer 
where you bought heater.

FRESH AIR FOR COMBUSTION AND 
VENTILATION

WARNING

: This heater shall not be installed in 

a confi ned space or unusually tight construction 
unless provisions are provided for adequate 
combustion and ventilation air. Read the following 
instructions to insure proper fresh air for this and 
other fuel-burning appliances in your home. 

ESTABLISHING ADEQUATE VENTILATION

The following are excerpts from 

National Fuel Gas 

Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for 
Combustion and Ventilation

. All spaces in homes fall 

into one of the three following ventilation classifi cations:

1. Unusually 

Tight 

Construction

2. Unconfi ned Space

3. Confi ned Space

This heater must not be installed in a confi ned space or 
unusually tight construction unless provisions are pro-
vided for adequate combustion and ventilation air. The 
information on pages 4 through 6 will help you classify 
your space and provide adequate ventilation.

Unusually Tight Construction 

If your home meets all of the three following criteria you 
must provide additional fresh air. See 

Ventilation Air 

from Outdoors

, page 6.

Unusually tight construction is defi ned as construction 
where:

a. Walls and ceilings exposed to the outside atmo-

sphere have a continuous water vapor retarder with 
a rating of one perm (6 x 10

-11

 kg per pa-sec-m

2

) or 

less with openings gasketed or sealed and

b. Weather stripping has been added on operable 

windows and doors, and 

c.  Caulking or sealants are applied to areas such 

as joints around windows and door frames, 
between wall-ceiling joints, between wall panels, at 
penetrations for plumbing, electrical, and gas lines, 
and at other openings. 

If your home does not meet all of the three criteria 
above, see 

Determine the Type of Heater Location 

Space

, page 5.

Confi ned Space and Unconfi ned Space

The National Fuel Gas Code, NFPA 54/ ANSI Z223.1 

defi nes a confi ned space as a space whose volume is 
less than 50 cubic feet per 1,000 Btu per hour (4.8 m

3

 

per kW) of the aggregate input rating of all appliances 
installed in that space, and an unconfi ned space as a 
space whose volume is not less than 50 cubic feet per 
1,000 Btu per hour (4.8 m

3

 per kW) of the aggregate 

input rating of all appliances installed in that space. 
Rooms communicating directly with the space in which 
the appliances are installed*, through openings not 
furnished with doors, are considered a part of the 
unconfi ned space.

Ignitor Button

Control Knob

Grill

Front Panel

Burners

Heater 
Cabinet

Fan Blower 
Switch

(located on back of 
heater)

*

Blower not included on all units

Содержание HSSVFB30NGBT

Страница 1: ...ediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed...

Страница 2: ...oxide poisoning WARNING This appliance is equipped for natural gas Field conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this h...

Страница 3: ...proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let coo...

Страница 4: ...om National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Cons...

Страница 5: ...hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount...

Страница 6: ...ces from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all appliance in both s...

Страница 7: ...vel For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joinin...

Страница 8: ...bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in openi...

Страница 9: ...re Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap...

Страница 10: ...d be plugged into a properly grounded three prong receptacle OPERATING YOUR HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may...

Страница 11: ...for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 When the pilot is lit turn control knob counterclockwise to heating level Th...

Страница 12: ...stled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit ever 2 500 hours of operation or every three months We also recommend that you keep the burner tube and p...

Страница 13: ...gas regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed...

Страница 14: ...ances see Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni...

Страница 15: ...15 Installation Instructions and Owner s Manual Unvented Natural Gas Vent Free Room Heaters This page intentionally left blank...

Страница 16: ...w Thermocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80074 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019...

Страница 17: ...1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse...

Страница 18: ...80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mou...

Страница 19: ...80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80083 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Moun...

Страница 20: ...mmunication LIMITED WARRANTY ENERCO Technical Products Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 5 year from date of purchase ENERCO...

Отзывы: