background image

20

Installation Instructions and Owner’s Manual

Unvented Natural Gas Vent Free Room Heaters

ENERCO Technical Products, Inc. reserves the right to make changes at any time, 
without notice or obligation, in colors, specifications, accessories, materials and 
models.

WARNING:

USE ONLY MANUFACTURERÊS REPLACEMENT PARTS. USE OF ANY OTHER PARTS 
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE 
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE 
AGENCY. 

REPLACEMENT PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased at any HEATSTAR by Enerco local 

dealer or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194
WWW.HEATSTARBYENERCO.COM
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.

Please include the model number, date of purchase, and description of problem in 
all communication.

LIMITED WARRANTY

ENERCO Technical Products, Inc. warrants its heaters and accessories to be free from 
defects in material and workmanship for a period of 5-year from date of purchase. 
ENERCO Technical Products, Inc. will repair or replace this product free of charge 
if it has been proven to be defective within the 5-year period, and is returned at 
customer expense with proof of purchase to ENERCO Technical Products, Inc. within 
the warranty period.

ENERCO Technical Products, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194
HEATSTAR is a registered trademarks of ENERCO Technical Products, Inc.
© 2016, ENERCO Technical Products. All rights reserved

ANSI Z21.11.2 - 2013

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. Place instructions in a safe 

place for future reference. Do not allow anyone who has not read these instructions to assemble, 
light, adjust or operate the heater.

PRODUCT REGISTRATION:  Thank you for your purchase.  
Please log in to http://www.egiregistration.com to register your product.

Содержание HSSVFB30NGBT

Страница 1: ...ediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed...

Страница 2: ...oxide poisoning WARNING This appliance is equipped for natural gas Field conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this h...

Страница 3: ...proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let coo...

Страница 4: ...om National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Cons...

Страница 5: ...hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount...

Страница 6: ...ces from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all appliance in both s...

Страница 7: ...vel For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joinin...

Страница 8: ...bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in openi...

Страница 9: ...re Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap...

Страница 10: ...d be plugged into a properly grounded three prong receptacle OPERATING YOUR HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may...

Страница 11: ...for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 When the pilot is lit turn control knob counterclockwise to heating level Th...

Страница 12: ...stled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit ever 2 500 hours of operation or every three months We also recommend that you keep the burner tube and p...

Страница 13: ...gas regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed...

Страница 14: ...ances see Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni...

Страница 15: ...15 Installation Instructions and Owner s Manual Unvented Natural Gas Vent Free Room Heaters This page intentionally left blank...

Страница 16: ...w Thermocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80074 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019...

Страница 17: ...1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse...

Страница 18: ...80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mou...

Страница 19: ...80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80083 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Moun...

Страница 20: ...mmunication LIMITED WARRANTY ENERCO Technical Products Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 5 year from date of purchase ENERCO...

Отзывы: