![HeatStar HSP100ID Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/heatstar/hsp100id/hsp100id_operating-instructions-and-owners-manual_2117835003.webp)
Installation Instructions and Owner’s Manual
Portable Indirect Oil-Fired Heaters
3
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
CLEARANCES TO COMBUSTIBLES
Clearances between these HEATSTAR PRO
indirect heaters and adjacent combustible
material (which is part of the building or its
contents) shall not be less than:
Top: 2ft (0.61m)
Sides: 2ft (0.61m)
Front: 5ft (1.524m)
If you need assistance or heater information such as a instructions manuals, labels, etc. contact the
manufacturer.
MODEL
HSP70ID
HSP100ID
HSP200ID
HSP300ID
Heat Input (kBTU/hr)
74.9
112
180
285
Air Flow (CFM)
910
1060
1060
1950
Fuel Types
• #1 or #2 Fuel Oil
• K-1 Kerosene
Fuel Consumption (gal/hr) 0.53
0.86
1.27
2.02
Tank Capacity (gal)
11.6
17
17
27.7
Danfoss Nozzle
Capacity (gal/hr)
Spray Angle (deg)
Spray Pattern
Capacity: 0.40
Angle: 80°
Pattern: Solid
Capacity: 0.65
Angle: 80°
Pattern: Solid
Capacity: 1.00
Angle: 80°
Pattern: Solid
Capacity: 1.5
Angle: 80°
Pattern: Solid
Pump Pressure (psi) [bar]
174 [12]
174 [12]
188 [13]
174 [12]
Power Supply
1 Phase, 120V,
60Hz, 3A
1 Phase, 120V,
60Hz, 7.5A
1 Phase, 120V,
60Hz, 13A
1 Phase, 120V,
60Hz, 11.4A
Power Consumption (kW) 0.36
0.9
1.6
1.4
Dimensions (L” x W” x H”) 45x15x26
48.5x22.5x39
53x22.5x39
63x28x37
Dry Weight (lb)
73
135
148
271
Full Weight, Diesel (lb)
156
257
270
469
Unlike direct combustion heaters, which send
combustion products into the space with hot
air, These HEATSTAR PRO indirect-fired keep
combustion products separated from clean hot
air by means of a heat exchanger. As combustion
occurs in the combustion chamber, combustion
by-products escape through the chimney
and away from the user through the options
described in “FRESH AIR AND VENTILATION” on
page 5. A fan blows clean ambient air across
the outside of the combustion chamber which
warms the air as it is pushed toward the space.
THEORY OF OPERATION
PRECAUTIONS
Caution:
When using Thermostat, heater
can start unexpectedly. Turn heater off when
unattended.
WARNING:
• DO NOT USE GASOLINE, NAPHTHA OR
VOLATILE FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM
OPEN FLAME
• DO NOT OPERATE HEATER WHERE
FLAMMABLE LIQUIDS OR VAPORS MAY BE
PRESENT
• DO NOT START HEATER WHEN EXCESS
FUEL HAS ACCUMULATED IN THE
CHAMBER
• DO NOT PLACE COOKING UTENSILS ON
TOP OF THE HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY
GROUNDED THREE-PRONG RECEPTACLE.
SPECIFICATIONS