HeatStar F156061 Скачать руководство пользователя страница 9

Installation Instructions and Owner’s Manual

Unvented LP-Gas Vent Free Room Heaters

9

CAUTION:

 Never connect heater directly to the Propane 

supply. This heater requires an external regulator (not 
supplied). Install the external regulator between the 
heater and Propane/LP supply. 

IMPORTANT:

 The installer must supply an external 

regulator. The external regulator will reduce the 
incoming gas pressure to between 11 and 14 
inches of water. If you do not reduce incoming gas 
pressure heater regulator damage could occur. 
Install external regulator with the vent pointing 
down. Pointing the vent down protects it from 
freezing rain or sleet.

CAUTION:

 Use only new black iron or steel pipe. 

Internally-tinned copper tubing may be used in certain 
areas. Check your local codes. Use pipe of large 
enough diameter to allow proper gas volume to heater. 
If pipe is too small, undue loss of pressure will occur. 

Installation must include an equipment shutoff valve, 
union and plugged 1/8” NPT tap. Locate NPT tap within 
reach of test gauge hookup. NPT tap must be upstream 
from heater (see fi gure 12).

Figure 12

*A CSA/AGA certifi ed equipment shutoff valve with
1/8” NPT tap is an acceptable alternative to test gauge 
connection. Purchase the CSA/AGA certifi ed equipment 
shutoff valve from your dealer. 

IMPORTANT:

 Install an equipment shutoff valve in an 

accessible location. The equipment shutoff valve is for 
turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. Excess 
sealant in pipe could result in clogged heater fuel train.

CAUTION:

 Use pipe joint sealant that is resistant to 

LP-Gas

Install sediment trap in supply line as shown in fi gure 
12. Locate sediment trap where it is within reach
for cleaning. A sediment trap traps moisture and 
contaminants. This keeps them from going into heater. 
If sediment trap is not installed or is installed improperly, 
heater may not run correctly.

Pressure 
Regulator

Heater 
Cabinet

Ground Joint Union

Equipment 
Shutoff Valve

From regulated LP tank
(11” W.C. to 14” W.C. 
Pressure)

Tee Joint

1/8” NPT Plug Tap

Cap

Pipe Nipple

Tee Joint

3/8” NPT Pipe Nipple

Sediment 
Trap

Test Gauge 
Connection

Reducer Bushing 
to 1/8” NPT

3” Minimum

IMPORTANT:

 Hold pressure regulator with wrench 

when connecting it to gas piping and/or fi ttings.

CHECKING GAS CONNECTIONS

WARNING:

 Test all gas piping and connections for 

leaks after installing or servicing. Correct all leaks 
at once. 

WARNING:

 Never use an open fl ame to check for 

a gas leak. Apply a mixture of liquid soap and water 
to all joints. Bubbles forming show a leak. Correct 
all leaks at once. 

PRESSURE TESTING GAS SUPPLY PIPING 
SYSTEM

Test pressure in Excess of ½ psig (3.5kPa)

1.

Disconnect appliance with its appliance main
gas valve (control valve) and equipment shutoff
valve from gas supply piping system. Pressures
in excess of ½ psig will damage heater
regulator.

2.

Cap off open end of gas pipe where equipment
shutoff valve was connected.

3.

Pressurize supply piping system by either using
compressed air or opening main gas valve on
or near gas meter.

4.

Check all connections and joints in gas supply
piping system. Apply mixture of liquid soap and
water to gas joints. Bubbles forming show a
leak.

5.

Correct all leaks at once.

6.

Depressurize and relieve pressure in supply
piping system.

7.

Reconnect heater and equipment shutoff valve
to gas supply.

8.

Reconnected 

fi ttings must be checked for leaks

in next section.

Test Pressure Equal To or Less Than ½ psig (3.5 kPa)

1.

Close equipment shutoff valve (see fi gure 13).

2.

Pressurize supply piping system by either using
compressed air or opening main gas valve on
or near gas meter.

3.

Check all joints from the gas meter to
equipment shutoff valve (see fi gure 14). Apply
mixture of liquid soap and water to gas joints.
Bubbles forming show a leak.

4.

Correct all leaks at once.

5.

Depressurize and relieve pressure from supply
piping system.

Содержание F156061

Страница 1: ...Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or gas supplier 2016 CB UNVENTED LP GAS FIRED ROOM HEATER OPERATING IN...

Страница 2: ...os on YouTube SOCIAL MEDIA WARNINGS IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning WARNING This appliance is equipped for propane gas Field conversion is not permitted WARNING Do not use any acce...

Страница 3: ...931W shall not be installed in a bedroom or bathroom 3 Keep all air openings in heater clear free of debris or any blockage This will insure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let cool before servicing Only a qualified ser...

Страница 4: ...ing are excerpts from National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space This heater must not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combus...

Страница 5: ... Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide addi...

Страница 6: ...learances from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all appliance in both spaces Ventilation from Outdoors If necessary provide extra fresh air by using ventilation grills or ducts Connect these items directly to the outdoors or spaces open to the outdoors These includ...

Страница 7: ...g bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joining wall 2 Mark screw locations on wall see figure 7 3 Remove tape and mount bracket from wall Figure 7 Attaching to Wall Stud For attaching mounting bracket to wall studs 1 Drill holes a...

Страница 8: ...ttom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighten both screws until heater is firmly se cured to wall Do not over tighten Note Do not re place front panel at this time Re place front panel after making gas co...

Страница 9: ...ng into heater If sediment trap is not installed or is installed improperly heater may not run correctly Pressure Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From regulated LP tank 11 W C to 14 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Reducer Bushing to 1 8 NPT 3 Minimum IMPORTANT Hold pressure...

Страница 10: ...fire department C Use only your hand to push in or turn the gas control knob Never use tools If knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion Pressure Testing Heater Gas Connections 1 The appliance and its appliance main gas valve must be disconnected from the gas supply p...

Страница 11: ... for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 When the pilot is lit turn control knob counterclockwise to heating level The main burner should light 9 To select the desired heat level turn the temperature setting knob counterclockwise to between 1 5 THERMOSTAT CONTROL OPERATION FOR IR20LPT IR30LPT The thermostatic contro...

Страница 12: ...be and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions that follow should...

Страница 13: ... regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple damaged 5 Control valve damaged 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 ...

Страница 14: ...e Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces unwa...

Страница 15: ...Unvented LP Gas Vent Free Room Heaters 15 Installation Instructions and Owner s Manual ...

Страница 16: ...rmocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019 Ignitor Module 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80106 Regulator 1 28 80068 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 80070 Burner Ri...

Страница 17: ...23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80082 Regulator 1 28 80068 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 80069 Burner Right Bracket 1...

Страница 18: ...0079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 23 80014 Ignitor Wire 1 11 80009 Orifice 1 24 80013 High Limit Switch Fan 1 12 80021 Bracket Plenum Assembly 1 25 80049 Fan Switch 1 13 70640 Thermostat Valve 1 70342 Hardware Kit not sh...

Страница 19: ...0079 Gas Input Elbow Adapter 1 30 801 10 Fan Assembly 1 8 80083 Regulator 1 31 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 32 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 33 80014 Ignitor Wire 1 11 80009 Orifice 1 34 80013 High Limit Switch Fan 1 12 80033 Bracket Plenum Assembly 1 35 80049 Fan Switch 1 13 70640 Thermostat Valve 1 70342 Hardware Kit not sh...

Страница 20: ...any HEATSTAR by ENERCO local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 www heatstarbyenerco com Our office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY HEATSTAR warrants its heaters and accessories to be free from defe...

Отзывы: