10

Installation Instructions and Owner’s Manual

Unvented LP-Gas Vent Free Room Heaters

Equipment 
Shutoff Valve

Open

Closed

ELECTRICAL WIRING DIAGRAM:

If any original wiring as supplied with the heater must 
be replaced, it must be replaced with type AWG 105

o

wire or its equivalent except as indicated.

WARNING:

 Electrical Grounding Instructions: This 

heater is equipped with a three-prong (grounding) 
plug for your protection against shock hazard and 
should be plugged into a properly grounded three-
prong receptacle. 

OPERATING YOUR HEATER

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:

 If you do not follow these instructions 

exactly, a fi re or explosion may result causing 
property damage, personal injury or loss of life. 

A.  This appliance has a pilot which must be lighted 

by pushing the ignitor button. When lighting the 
pilot, follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the 
fl oor because some gas is heavier than air and 
will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use
any phone in your building.

Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.

If you can not reach your gas supplier, call the
fi re department.

C.  Use only your hand to push in or turn the gas 

control knob. Never use tools. If knob will not 
push in or turn by hand, don’t try to repair it call 
a qualifi ed service technician or gas supplier. 
Force or attempted repair may result in a fi re or 
explosion.

Pressure Testing Heater Gas Connections:

1.

The appliance and its appliance main gas valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 

½

psi (3.5 kPa). The appliance must be isolated
from the gas supply piping system by closing
its equipment shutoff valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 

½

 psi (3.5 kPa).

2.

Make sure control knob of heater is in OFF
position.

3.

Open equipment shutoff valve (see fi gure 13).

4.

Open main gas valve on or near gas meter.

5.

Check all joints from equipment shutoff valve
to control valve (see fi gure 14). Apply mixture
of liquid soap and water to gas joints. Bubbles
forming show a leak.

6.

Correct all leaks at once.

7.

Light heater (see 

Operating Your Heater

, pages

10 and 11. Check the rest of the internal joints
for leaks.

8.

Turn off heater (see 

To Turn OFF Gas to

Appliance

, page 11.

9.

Replace lower front panel.

Figure 13

Figure 14

Control Valve

Equipment 
Shutoff Valve

To regulated propane 
source

Caution:

  Label all wires prior to 

disconnection when 
servicing controls. 
Wiring errors can cause 
improper and dangerous 
operation. Verify proper 
operation after servicing.

Figure 15

Содержание F156061

Страница 1: ...Combustion and Ventilation section on page 4 of this manual WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or gas supplier 2016 CB UNVENTED LP GAS FIRED ROOM HEATER OPERATING IN...

Страница 2: ...os on YouTube SOCIAL MEDIA WARNINGS IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning WARNING This appliance is equipped for propane gas Field conversion is not permitted WARNING Do not use any acce...

Страница 3: ...931W shall not be installed in a bedroom or bathroom 3 Keep all air openings in heater clear free of debris or any blockage This will insure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let cool before servicing Only a qualified ser...

Страница 4: ...ing are excerpts from National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space This heater must not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combus...

Страница 5: ... Vent Free Heater 20 000 Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide addi...

Страница 6: ...learances from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all appliance in both spaces Ventilation from Outdoors If necessary provide extra fresh air by using ventilation grills or ducts Connect these items directly to the outdoors or spaces open to the outdoors These includ...

Страница 7: ...g bracket is level For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joining wall 2 Mark screw locations on wall see figure 7 3 Remove tape and mount bracket from wall Figure 7 Attaching to Wall Stud For attaching mounting bracket to wall studs 1 Drill holes a...

Страница 8: ...ttom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighten both screws until heater is firmly se cured to wall Do not over tighten Note Do not re place front panel at this time Re place front panel after making gas co...

Страница 9: ...ng into heater If sediment trap is not installed or is installed improperly heater may not run correctly Pressure Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From regulated LP tank 11 W C to 14 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Reducer Bushing to 1 8 NPT 3 Minimum IMPORTANT Hold pressure...

Страница 10: ...fire department C Use only your hand to push in or turn the gas control knob Never use tools If knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion Pressure Testing Heater Gas Connections 1 The appliance and its appliance main gas valve must be disconnected from the gas supply p...

Страница 11: ... for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 When the pilot is lit turn control knob counterclockwise to heating level The main burner should light 9 To select the desired heat level turn the temperature setting knob counterclockwise to between 1 5 THERMOSTAT CONTROL OPERATION FOR IR20LPT IR30LPT The thermostatic contro...

Страница 12: ...be and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions that follow should...

Страница 13: ... regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple damaged 5 Control valve damaged 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds 3 ...

Страница 14: ...e Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater produces unwa...

Страница 15: ...Unvented LP Gas Vent Free Room Heaters 15 Installation Instructions and Owner s Manual ...

Страница 16: ...rmocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019 Ignitor Module 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80106 Regulator 1 28 80068 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 80070 Burner Ri...

Страница 17: ...23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80082 Regulator 1 28 80068 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 80069 Burner Right Bracket 1...

Страница 18: ...0079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 23 80014 Ignitor Wire 1 11 80009 Orifice 1 24 80013 High Limit Switch Fan 1 12 80021 Bracket Plenum Assembly 1 25 80049 Fan Switch 1 13 70640 Thermostat Valve 1 70342 Hardware Kit not sh...

Страница 19: ...0079 Gas Input Elbow Adapter 1 30 801 10 Fan Assembly 1 8 80083 Regulator 1 31 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 32 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 33 80014 Ignitor Wire 1 11 80009 Orifice 1 34 80013 High Limit Switch Fan 1 12 80033 Bracket Plenum Assembly 1 35 80049 Fan Switch 1 13 70640 Thermostat Valve 1 70342 Hardware Kit not sh...

Страница 20: ...any HEATSTAR by ENERCO local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 www heatstarbyenerco com Our office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY HEATSTAR warrants its heaters and accessories to be free from defe...

Отзывы: