TROUBLESHOOTING
625ES Electrical Box Pictured
Figure 1
A
B
Symptom
Possible Solution
No power to the
unit.
Verify the unit is plugged into a 20 Amp, GFCI circuit and the Power Switch is set to the “ON” posi-
tion.
Is the GFCI circuit breaker tripped?
1) Remove “Non-Stick” Cover and inspect the Seal Plate for the following defects***:
Punctures or cuts.
Burn marks.
Extreme discoloration (blue/black or gold).
2) Ensure the GFCI circuit being utilized is not overloaded with other devices.
***If a surface defect is present, discontinue use of product and contact
Troy Roberts at:
800-342-6329 ext 276 or [email protected]
Seal Plate is work-
ing but the Red
Indicator Light is
not working proper-
ly.
If the Red Indicator Light does not turn ON or OFF as expected, verify that the Red Indicator Light
Timer is functioning properly. Replace Timer Board Assembly as required (Part #1818-026).
Verify 120V is being supplied to the light when the Seal Plate is actuated. If voltage is present, re-
place the Rocker Arm Assembly Kit (Part #6340-076)
Revised 201
7
9