![Heatscope MHS-NM2400 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/heatscope/mhs-nm2400/mhs-nm2400_original-installation-and-instruction-manual_2117754007.webp)
A M B I E N T H E A T I N G S O L U T I O N S
may only be replaced by a professional servicing company enlisted by the manufacturer.
The supply cable must be connected generally in a commercially available wet room
distribution box with IP65 protection class acc. to IEC or UL / CSA (not within the scope of
supply).
3. The HEATSCOPE
®
is protected against splashing water and has an IP65 protection class
rating.
4. As soon as the unit is connected to a power source and switched on using an „ON/OFF“
switch or other operating component, it takes a maximum of 15-30 seconds until it
reaches its operating temperature.
5. CAUTION: Risk of burns! The front screen (approx. 300°C) and protective fin front
(approx. 400°C) gets very hot when the unit is operating. Do not cover either part of the
front or the entire front of the radiant heater. Do not touch any part of the HEATSCOPE
®
during operation and up to 30 minutes after switching it off.
6. For your own safety, never dry textiles or other materials using the HEATSCOPE
®
. Covering
the radiant heater may result in a fire! Always maintain a distance from the heating sur
-
face of the HEATSCOPE
®
of at least 150 cm from textiles, cloth and other easy inflamma
-
ble soft materials.
7. Ensure that cables, furniture, flammable materials or other objects do not come into
contact with the surface of the radiant heater and never cover the unit. Under no cir
-
cumstances should the unit be covered or enclosed with insulating or similar materials.
Adequate ventilation surrounding the heater must be ensured at any time. Ledgers,
beams and rafters must not be cut into or grooved to install the infrared heater. When
installing the HEATSCOPE
®
radiant heater, ensure that the lower edge of the unit is at
least 180 cm from the ground and the safety clearances from the wall and ceiling set out
in this manual are maintained. Always maintain a distance from the heating surface of
the HEATSCOPE
®
of at least 150 cm from textiles, cloth and other easy inflammable soft
materials.
8. Disconnect the radiant heater from the power supply before cleaning it, adjusting the
angle or removing it from the wall/ceiling. Wait until the heating elements are not glowing
any more and the housing is noticably cooled down. If buried cables are used, switch off
the power using an omnipolar switch.
9. The HEATSCOPE
®
features an omnipolar „ON/OFF“ switch. The unit can be controlled
manually using an selector switch on the unit itself. The unit must be connected to a
residual current circuit breaker and a fuse on the installation side.
10. The unit must only be used with an approved isolating system, which must be built in
the existing electrical installation acc. to the facility regulations. The heater comes as
standard with a separate open-ended cable for connection purposes.
EN
Содержание MHS-NM2400
Страница 15: ...A M B I E N T H E A T I N G S O L U T I O N S VERSION 02 MONTAGE MOUNTING MONT VERSION 01...
Страница 16: ...2 1 MONTAGE MOUNTING MONT 1X 1X...
Страница 17: ...A M B I E N T H E A T I N G S O L U T I O N S 3 4 5 6...
Страница 19: ...A M B I E N T H E A T I N G S O L U T I O N S 15cm 180cm X X 40cm 40cm 200cm 40cm 200cm 40cm...
Страница 20: ...200cm 15cm X MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 10cm X 150cm...
Страница 22: ...MINDESTABST NDE MINIMUM DISTANCES MINIM LN VZD LENOST 200cm 40cm 40cm 180cm 40cm 40cm...
Страница 23: ...A M B I E N T H E A T I N G S O L U T I O N S 200cm 40cm 40cm 40cm...