1.0 IMPORTANT INSTALLATION
POINTS

1.1 The Supreme stores and dispenses water at or close to boiling

point at all times it is switched on.  Due caution must be taken
when choosing a location for the product to minimise misuse.
Locate the unit over a draining board NOT over the sink or basin.

1.2 Push fit connectors DO NOT grip chromed or stainless pipe.
1.3 The Supreme is a vented water heater.  The vent pipe must never

be blocked or obstructed, it must be a minimum of 15mm outside
diameter pipe.  Where the vent pipe length exceeds 3m the pipe
diameter should be increased. The vent pipe must be laid to a
continuous fall and discharge in a safe, visible position; it must
discharge via a tundish or finish a minimum of 20 mm above a
draining board.  The vent pipe material must be capable of
conveying boiling water.  The vent pipe must never be connected
directly to a soil pipe.

1.4 Wherever possible the Supreme should be supplied directly from

a rising main.  If fed from a cold water feed cistern, the cistern
must comply with the Water Regulations Guide (clause R27.2).
It should be noted that water quality may be reduced when
supplied from a cistern and additional forms of water pretreatment
may be necessary.

1.5 In hard water areas, heated water will produce limescale which

will be deposited within the heater.  If this is not regularly removed
it will impair the operation of the heater (see Supreme
Maintenance Plan).  Where rapid and excessive scale build up is
likely to occur the use of a proprietary scale reducing device may
be beneficial.

1.6 The installation must comply with the relevant sections of the

Water Regulations, Building Regulations and BS 7671 (IEE
Wiring Regulations) in force at the time.

1.7 The Supreme will adjust for ambient (room) temperatures of

between 1°C and 40°C.

1.8 When not in use care must be taken to prevent it freezing; if

thought to be frozen it must not be switched on.  It must be left to
thaw and must then be thorougly inspected to ensure it is totally
thawed and undamaged.

1.9 The unit is not suitable for installation in an area where a water jet

could be used.

Содержание SUPREME 150SS

Страница 1: ...1 Fitting Instructions and User Guide SUPREME 150SS 165SS 180SS...

Страница 2: ...ion should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissioning the operation of the heater should be explained to the customer and these instructions l...

Страница 3: ...ents have been supplied with your Supreme heater Wall mounting bracket No 12 x 2 screws 2 off No 8 x 1 screw 1 off No 12 x 2 wall plug 2 off No 8 x 1 wall plug 1 off Template to aid in positioning the...

Страница 4: ...ing main If fed from a cold water feed cistern the cistern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern a...

Страница 5: ...e work surface 2 3 Sufficient room should be left around the heater for access for maintenance and servicing The top should not be covered as this will reduce the efficiency of the Supreme 2 4 Ensure...

Страница 6: ...6 Fig 2 B A D E F 250 approx C G MODEL A B C D E F G OUTLET INLET VENT CABLE ENTRY 150SS 423 337 203 160 80 112 111 165SS 501 337 203 160 101 133 101 180SS 506 337 262 220 101 133 101 DIMENSIONS mm...

Страница 7: ...isolating valve should be fitted to the cold supply to facilitate servicing the heater 4 6 Push fit connectors are supplied to allow either bottom or rear entry of services If a combination of entry p...

Страница 8: ...ided unless using rear cable entry 6 5 Strip the outer sheath from the cable for a maximum of 60mm Prepare and consolidate the ends and connect the cable to the terminal block as follows BROWN or RED...

Страница 9: ...calibration procedure is interrupted it will restart after a short delay but may result in the calibrated temperature being too low If this occurs switch the electrical supply OFF for several seconds...

Страница 10: ...solenoid valve 8 3 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas However some deposits may still occur in the s...

Страница 11: ...supply Unit does not heat on commissioning 1 If ON indicator not illuminated no power to unit 1 Check power supply is correctly connected and switched on and that primary cutout has not operated 2 If...

Страница 12: ...ry 3 Scale build up 3 Descale unit Drips from outlet 1 Incorrect spring tension 1 Ensure tap headwork nut correctly adjusted 2 Scale debris under tap seal 2 Remove and clean as necessary 3 Damaged tap...

Страница 13: ...165 180 models 95 615 007 8 Wiring harness 4way inc diodes 95 612 006 9 Wiring harness complete 95 612 013 10 Thermistor control steam 95 612 696 11 Outlet tap headwork inc handle 95 605 019 12 Outle...

Страница 14: ...5 model 95 607 022 33 Inlet injector assembly 180 model 95 607 026 34 Tank 150 model 95 608 926 35 Tank 165 model 95 608 927 36 Tank 180 model 95 608 928 37 Tank drain seal 95 608 929 38 Start dry cut...

Страница 15: ...OR EARTH UPPER LEVEL SENSOR LOWER LEVEL SENSOR SCALE CONDITIONING FIELD WINDING AT TEMP LED ANODE AT TEMP LED CATHODE POWER ON LED ANODE POWER ON LED CATHODE WIRING SCHEMATIC H N W L1 L2 L3 BACK PLATE...

Страница 16: ...e electrical supply to the Supreme is switched on READY When fully illuminated indicates that the stored water is hot enough to use 11 5 If the store of hot water is completely withdrawn the flowrate...

Страница 17: ...s been regularly maintained as detailed in the maintenance instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost or due to the build u...

Страница 18: ...18 NOTES...

Страница 19: ...19...

Страница 20: ...Center Network 65 Buisness Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Newey Eyre Specialists Products Division Please contact your local branch UK Spares...

Отзывы: