Any faults that cannot be identified using the Fault Finding chart, or in
case of doubt, contact the Heatrae Sadia Service Department,
telephone (01603) 420330, fax (01603) 420349.

SYMPTOM

POSSIBLE  CAUSE

ACTION

Water flows from vent and primary 
cutout activates

1.  Solenoid valve fault

1.  Check operation of solenoid valve, 
replace if necessary

2.  Level sensor fault 

2.  Check level system earth 
connections

3.  Electronic control fault

3.  Check connections to electronic 
control.  Replace if necessary

Steam from vent pipe and primary 
cutout operates

1. Control thermistor fault – open 
circuit  

3.  Check continuity (5Kohms at 
100°C , 100Kohms at 25°C)

2.  Electronic control fault

2.  Check connections to electronic 
control.  Replace if necessary

3.  Scale build up

3.  Descale unit

Drips from outlet

1.  Incorrect spring tension

1.  Ensure tap headwork nut correctly 
adjusted

2.  Scale

 :

 debris under tap seal

2.  Remove and clean as necessary

3.  Damaged tap seal

3.  Replace tap seal

4.  Scale on tap outlet spout

4.  Clean tap outlet

Water “runs on” when tap released

1.  Scale on tap outlet spout

1.  Clean tap outlet

2.  Scale 

:

 debris under tap seal

2.  Remove and clean as necessary

3.  Damaged tap seal

3.  Replace tap seal

Stale taste to water

Unit left unused for several days

Empty and allow to refill before use

Tap sticks open

Dirt around handle pivot

Clean with a stiff paint brush

Water consistently cooler than when 
new

1.  Control thermistor pocket has a 
covering of scale

1.  Descale the pocket surface & unit

2.  Control thermistor out of 
calibration 

2. Check values (5Kohms at 100°C, 
100Kohms at 25°C)

3.  Steam thermistor out of calibration 3. Check values (5Kohms at 100°C, 

100Kohms at 25°C)

Содержание SUPREME 150SS

Страница 1: ...1 Fitting Instructions and User Guide SUPREME 150SS 165SS 180SS...

Страница 2: ...ion should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissioning the operation of the heater should be explained to the customer and these instructions l...

Страница 3: ...ents have been supplied with your Supreme heater Wall mounting bracket No 12 x 2 screws 2 off No 8 x 1 screw 1 off No 12 x 2 wall plug 2 off No 8 x 1 wall plug 1 off Template to aid in positioning the...

Страница 4: ...ing main If fed from a cold water feed cistern the cistern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern a...

Страница 5: ...e work surface 2 3 Sufficient room should be left around the heater for access for maintenance and servicing The top should not be covered as this will reduce the efficiency of the Supreme 2 4 Ensure...

Страница 6: ...6 Fig 2 B A D E F 250 approx C G MODEL A B C D E F G OUTLET INLET VENT CABLE ENTRY 150SS 423 337 203 160 80 112 111 165SS 501 337 203 160 101 133 101 180SS 506 337 262 220 101 133 101 DIMENSIONS mm...

Страница 7: ...isolating valve should be fitted to the cold supply to facilitate servicing the heater 4 6 Push fit connectors are supplied to allow either bottom or rear entry of services If a combination of entry p...

Страница 8: ...ided unless using rear cable entry 6 5 Strip the outer sheath from the cable for a maximum of 60mm Prepare and consolidate the ends and connect the cable to the terminal block as follows BROWN or RED...

Страница 9: ...calibration procedure is interrupted it will restart after a short delay but may result in the calibrated temperature being too low If this occurs switch the electrical supply OFF for several seconds...

Страница 10: ...solenoid valve 8 3 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas However some deposits may still occur in the s...

Страница 11: ...supply Unit does not heat on commissioning 1 If ON indicator not illuminated no power to unit 1 Check power supply is correctly connected and switched on and that primary cutout has not operated 2 If...

Страница 12: ...ry 3 Scale build up 3 Descale unit Drips from outlet 1 Incorrect spring tension 1 Ensure tap headwork nut correctly adjusted 2 Scale debris under tap seal 2 Remove and clean as necessary 3 Damaged tap...

Страница 13: ...165 180 models 95 615 007 8 Wiring harness 4way inc diodes 95 612 006 9 Wiring harness complete 95 612 013 10 Thermistor control steam 95 612 696 11 Outlet tap headwork inc handle 95 605 019 12 Outle...

Страница 14: ...5 model 95 607 022 33 Inlet injector assembly 180 model 95 607 026 34 Tank 150 model 95 608 926 35 Tank 165 model 95 608 927 36 Tank 180 model 95 608 928 37 Tank drain seal 95 608 929 38 Start dry cut...

Страница 15: ...OR EARTH UPPER LEVEL SENSOR LOWER LEVEL SENSOR SCALE CONDITIONING FIELD WINDING AT TEMP LED ANODE AT TEMP LED CATHODE POWER ON LED ANODE POWER ON LED CATHODE WIRING SCHEMATIC H N W L1 L2 L3 BACK PLATE...

Страница 16: ...e electrical supply to the Supreme is switched on READY When fully illuminated indicates that the stored water is hot enough to use 11 5 If the store of hot water is completely withdrawn the flowrate...

Страница 17: ...s been regularly maintained as detailed in the maintenance instructions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost or due to the build u...

Страница 18: ...18 NOTES...

Страница 19: ...19...

Страница 20: ...Center Network 65 Buisness Park Bentley Wood Way Burnley Lancashire BB11 5ST Tel 01282 834403 www partscenter co uk Newey Eyre Specialists Products Division Please contact your local branch UK Spares...

Отзывы: