Heatrae Sadia SUPREME 150 Скачать руководство пользователя страница 4

4

1.0 IMPORTANT INSTALLATION POINTS

1.1 The Supreme stores and dispenses water at or close to boiling 

point at all times it is switched on. Due caution must be taken when 
choosing a location for the product to minimise misuse.  Locate the 
unit over a draining board NOT over the sink or basin.

1.2  Push fit connectors DO NOT grip chromed or stainless pipe.
1.3 The Supreme is a vented water heater. The vent pipe must never 

be blocked or obstructed, it must be a minimum of 15mm outside 
diameter pipe. Where the vent pipe length exceeds 3m the pipe 
diameter should be increased. The vent pipe must be laid to a 
continuous fall and discharge in a safe, visible position; it must 
discharge via a tundish or finish a minimum of 20mm above a draining 
board. The vent pipe material must be capable of conveying boiling 
water. The vent pipe must never be connected directly to a soil pipe.

1.4 Wherever possible the Supreme should be supplied directly from 

a rising main. If fed from a cold water feed cistern, the cistern must 
comply with the Water Regulations Guide (clause R27.2).

 

It should be noted that water quality may be reduced when supplied 
from a cistern and additional forms of water pre-treatment may be 
necessary.

1.5  In hard water areas, heated water will produce limescale which will 

be deposited within the heater. If this is not regularly removed it will 
impair the operation of the heater. Where rapid and excessive scale 
build up is likely to occur the use of a proprietary scale reducing 
device may be beneficial.

1.6  The installation must be carried out in accordance with the relevant 

requirements of:      

•  The appropriate Building Regulations either The Building 

Regulations, The Building Regulations (Scotland) or Building 
Regulations (Northern Ireland). 

•  The Water Fittings Regulations or Water Byelaws in 

Scotland.

1.7  The Supreme will adjust for ambient (room) temperatures of between 

1°C and 40°C.

1.8  When not in use care must be taken to prevent it freezing; if thought 

to be frozen it must not be switched on. It must be left to thaw and 
must then be thorougly inspected to ensure it is totally thawed and 
undamaged.

1.9 The unit is not suitable for installation in an area where a water jet 

could be used.

Содержание SUPREME 150

Страница 1: ...Supreme 150SS 165SS 180SS Fitting Instructions and User Guide...

Страница 2: ...and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved Cleaning and user maintenance shall not be made b...

Страница 3: ...bow push fit connector TECHNICAL SPECIFICATIONS Electrical rating 2 3 2 5 kW 230 240V Nominal capacities Model 150SS 2 5 litres Model 165SS 5 0 litres Model 180SS 7 5 litres Weight full Model 150SS 12...

Страница 4: ...istern must comply with the Water Regulations Guide clause R27 2 It should be noted that water quality may be reduced when supplied from a cistern and additional forms of water pre treatment may be ne...

Страница 5: ...heater for access for maintenance and servicing The top should not be covered as this will reduce the efficiency of the Supreme 2 4 Ensure that the wall can support the full weight of the unit see TEC...

Страница 6: ...MENSIONS B A D E F 250 approx C G MODEL A B C D E F G OUTLET INLET VENT CABLE ENTRY 150SS 423 337 203 160 80 112 111 165SS 501 337 203 160 101 133 101 180SS 506 337 262 220 101 133 101 DIMENSIONS mm F...

Страница 7: ...et pipe run is horizontal and beneath the unit ensure it does not prevent access to the case screws 4 4 Connect the inlet pipe to the push fit connector ensuring it is fully pushed home 28mm engagemen...

Страница 8: ...connection 5 3 Connect the vent pipe to the push fit connector ensuring it is pushed fully home 28mm engagement Refer to the vent pipe requirements detailed in IMPORTANT INSTALLATION POINTS p4 If a b...

Страница 9: ...switching the unit off It is recommended that this is done automatically by incorporating a suitable timeswitch in the supply to the unit The use of an accessory no 95 970 124 is recommended The times...

Страница 10: ...inated If for any reason the calibration procedure is interrupted it will restart after a short delay but may result in the calibrated temperature being too low If this occurs switch the electrical su...

Страница 11: ...le conditioning function which will reduce the rate of scale deposition in hard water areas However some deposits may still occur in the storage tank these should be periodically removed 8 2 The amoun...

Страница 12: ...system 3 Check connections to electronic control Replace if necessary 4 Increase inlet pressure Steam from vent pipe and primary cutout operates 1 Control thermistor fault open circuit 2 Electronic c...

Страница 13: ...scale detected The unit requires cleaning and de scaling Power light gives 2 flashes and the unit shuts down There is no water Check water supply to the unit is avail able and turned on Power light gi...

Страница 14: ...4 005 12 Steam condenser assy 2 5ltr Model 95 607 015 Steam condenser assy 5 0ltr Model 95 607 016 Steam condenser assy 7 5ltr Model 95 607 018 13 Condenser sealing gasket 2 5ltr Model 95 611 817 Cond...

Страница 15: ...15 11 4 23 19 3 12 13 14 6 7 8 9 10 18 14 16 15 21 14 2 1 5 29...

Страница 16: ...g rate of the heater This slow flowrate allows the incoming water to be instantly reheated it does not indicate a fault with the water heater 11 6 If the Supreme is not used for a few days the water m...

Страница 17: ...been regularly maintained as detailed in the maintenance instructions 4 The unit has been used only for heating potable water The unit is warranty does not cover against damage by frost or due to the...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...ate responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the n...

Отзывы: