10. Decommissioning
10.1 Decommissioning procedure
`
Isolate electrical supplies and make safe
`
Isolate the water supply
`
Drain the product
`
Remove the product
`
Cap pipework
Environmental information
Products are manufactured from many recyclable
materials. At the end of their useful life they should
be disposed of at a Local Authority Recycling Centre
in order to realise the full environmental benefits.
9. Troubleshooting
9.1 General
Your product should give trouble free operation.
However if a problem occurs the table below should
allow most faults to be identified. Fault finding should
only be carried out by a competent person.
For any faults that cannot be identified using the
fault finding chart please contact the Heatrae Sadia
Service Department.
Symptom
Possible cause
Remedy
1. Water too hot
A. Water flow too low
Increase the flow by turning the stop valve
2. Water too cold
A. Electrical power to the
Multipoint heater is off
Ensure that the electrical supply to the Multipoint
B. Water flow too high
Reduce the flow by adjusting the water control
isolating valve
C. Element fault
Check for open circuit
3. Temperature
varies while
showering, cycling
hot/cold
A. Pressure switch is operating,
normally making a "click" as it
does so
Check water pressure/flow
B. Input pressure is below 1.0 bar
(14.5psi); flow is not stable
Ensure that your stop cock and servicing valve
are opened fully
4. "Power on"
indicator not lit.
Isolating switch "ON"
but its neon not lit
A. Cartridge fuse or miniture
circuit breaker (mcb) has
operated in your fusebox (or
consumer unit) or switch fuse
Switch off Multipoint Instantaneous and isolating
switch. Renew fuse, reset the mcb. If they
operate a second time, contact a qualified
electrician
B. Residual current device (rcd)
or (earth leakage circuit breaker)
has operated
Follow the same procedure as above. If this has
happened with a "split load" consumer unit on
initial installation, check that the neutral core
of the Multipoint Instantaneous feed cable is
connected to the "protected" neutral bar of the
unit
5. Water emerges
from expansion
relief valve
A. Expansion relief valve has
operated
1. Switch off immediately at isolating switch
2. Turn water off at the servicing valve (if fitted)
or stop valve
3. Contact Heatrae Sadia Service Department
6. No water flows
with valve open
A. Water supply turned off
Turn on water supply
B. Unit frozen
Turn OFF ELECTRICITY at isolating switch
and contact installer DO NOT USE THE
MULTIPOINT INSTANTANEOUS