Heatrae Sadia Multipoint 10 and 15 litre Скачать руководство пользователя страница 6

6

4.2 Operation principle

The product is used to heat and store hot water for 

use in domestic applications.

4.3 Standard delivery

 

`

Product

 

`

Fixing bracket

 

`

Screw pack

 

`

Instructions

4.4 Mains connections

See figure 4-6 below.

4.  Description of the product

4.1 General description

This product is a purposed designed unvented water 

heater. The product has a copper inner vessel, 

which ensures an excellent standard of corrosion 

resistance. The outer casing is a combination of 

resilient thermoplastic moldings and painted steel. 

The product is supplied complete with all the necessary 

safety and control devices needed to allow connection 

to the cold water mains. These components are preset 

and should not be tampered with.

Temperature 

and pressure 

relief valve

Temperature 

and pressure 

relief valve

Pressure

relief

(expansion)

valve

Note: If pressure reducing valve is 

used expansion down the mains is not possible

Pressure

relief

(expansion)

valve

Pressure

relief

(expansion)

valve

Expansion

vessel

Expansion

vessel

Service valve

Service valve

Hot

Cold

Hot

Cold

Check

Valve

Check

Valve

Check

Valve

Nearest cold 

draw off

Nearest cold 

draw off

Nearest cold 

draw off

Service valve

(fixed jumper or

1/4 turn ball type)

Cold

water

mains

Cold

water

mains

Cold

water

mains

Tundish

Tundish

Tundish

Multipoint

10 litre

or 15 litre

heater

Multipoint

10 litre

or 15 litre

heater

Temperature 

and pressure 

relief valve

Hot

Cold

Multipoint

10 litre

or 15 litre

heater

To drain (waste)

To drain (waste)

To drain (waste)

2.8 (10 l) or 4.2 (15 l) 

metres is required for 

expansion in pipework

Figure 4 – For inlet pressure up to 0.41 MPa (4.1 bar)

Figure 5 – For inlet pressure up to 0.41 MPa (4.1 bar) 

where expansion in mains supply is not possible

Figure 6 – For inlet pressure above 0.41 MPa (4.1 bar) 

Содержание Multipoint 10 and 15 litre

Страница 1: ...Multipoint 10 and 15 litre Fitting Instructions...

Страница 2: ...cise warranty details to customers Contents 1 Introduction 3 1 1 General 3 1 2 Symbols used 3 1 3 Abbreviations 3 1 4 Liabilities 3 2 Safety 4 2 1 General safety warnings 4 2 2 Recommendations 4 2 3 S...

Страница 3: ...in product quality All the specifications stated in this document are therefore subject to change without notice Our liability as the manufacturer may not be invoked in the following cases Failure to...

Страница 4: ...in any circumstance 2 Safety 2 1 General safety warnings DANGER This product is unvented and as such becomes pressurised when in operation The combination of pressurisation and hot water could lead t...

Страница 5: ...maintained and disposed of at end of life See Section 3 11 Electrical rating 3kW 240V 2 75kW 230V 4 5kW 240V 4 1kW 230V Capacities 10 or 15 litres Weight full 10 litre 16 9kg 15 litre 23 8kg Rated pr...

Страница 6: ...relief valve Pressure relief expansion valve Note If pressure reducing valve is used expansion down the mains is not possible Pressure relief expansion valve Pressure relief expansion valve Expansion...

Страница 7: ...gineer in accordance with prevailing and national regulations as listed below Building Regulations The Building Standards Scotland The Building Regulations Northern Ireland I E E Electrical Regs UK Wa...

Страница 8: ...environment The pipe from the valves to the tundish should be 15mm o dia minimum From the tundish to the point of discharge the pipe should be 22mm o dia minimum and have a resistance to flow equivale...

Страница 9: ...t be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations The pro...

Страница 10: ...l After filling the installation with water in the previous section please follow the following steps to complete the installation of the product WARNING DO NOT switch on the product until it has been...

Страница 11: ...d when using in conjunction with a Thermostatic Blending Valve position To lock the thermostat position the instructions given under Sections 4 2 3 or 4 2 4 should be followed We recommend that this p...

Страница 12: ...y by unscrewing the five securing screws a tapped jacking point is provided Remove any loose scale from the container Carefully clean off any scale from the element and thermostat pocket DO NOT clean...

Страница 13: ...relief valve intermittently A Expansion in mains not possible A Fit pack U2 see important installation points B Mains pressure exceeds 0 41 MPa 4 1 bar B Fit packs U1 and U2 C Pack U1 fitted without...

Страница 14: ...oduct is manufactured from many recyclable materials At the end of its useful life it should be disposed of at a Local Authority Recycling Centre to realise the full environmental benefits Insulation...

Страница 15: ...hin 60 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product The product is not covered against damage by frost and the imme...

Страница 16: ...sponsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the need to...