9.1 Important
i) Servicing should only be carried out by competent installers in the installation and maintenance of water
heating systems.
ii) Any spare parts used
MUST
be authorised Heatrae Sadia parts.
iii) Disconnect the electrical supply before removing any electrical equipment covers.
iv)
NEVER
bypass any thermal controls or operate system without the necessary safety controls.
v) Water contained in the Megalife solar unit may be very hot, especially following a thermal control failure.
Caution must be taken when drawing water from the unit.
9.2 Spare Parts
A full range of spare parts are available for the Megalife solar range. Refer to the technical data label on the unit to
identify the model installed and ensure the correct part is ordered.
9: Fault Finding and Servicing
2
9
6
4
5
8
3
1
Fig. 08: Spares
10
Item
Description
Part Number
1
Immersion heater (lower)
95 606 984
2
Immersion heater gasket
95 611 822
3
Immersion heater backnut
95 607 869
4
Direct combined thermostat and thermal cut-out
(spade terminals including wires and terminal block).
Direct combined thermostat and thermal cut-out
(spade terminals NO wires or terminal block).
95 612 720
95 612 721
5
Indirect combined thermostat and thermal cut-out
(spade terminals including wires and terminal block).
Indirect combined thermostat and thermal cut-out
(spade terminals NO wires or terminal block).
95 612 719
95 612 722
6
6 way terminal block
95 607 933
7
Immersion heater key
95 607 861
8
Terminal cover
95 614 095
9
Terminal Shroud
95 606 993
10
Solar temperature probe pocket
95 607 064
Table 01: Spares
36005941_issue_07.indd 14
07/09/2017 08:40:39