3.6 ELECTRICAL REQUIREMENTS

WARNING: This appliance must be earthed. It is suitable for a.c. supply only. 

Electrical installation must be carried out by a competent electrician and be 

in accordance with the latest I.E.E wiring regulations.

Ensure the electrical supply is switched off before making any connections 

to the water heater.

3.6.1  The unit is supplied fitted with a 0.75m 3 core 1.5mm

2

 flexible cable. 

The electricity supply should be fused 13 Amp and be via a double pole 

isolating switch with a contact separation of at least 3mm in both poles. 

Refer to Fig. 06 below.

3.6.2

  

The wires are colour coded as follows:

 

Green and Yellow  

EARTH  

 

Brown    

 

LIVE    

(L)

 

Blue  

 

 

NEUTRAL  

(N)

ELEMENT

NEON

RESET BUTTON

EARTH

POST

(STAT/CUT-OUT 

PLUGS DIRECTLY 

ONTO ELEMENT

TERMINATIONS).

DOUBLE POLE

ISOLATING SWITCH

BROWN

BLUE

GREEN/YELLOW

MAINS

SUPPLY

L

N

FIGURE 06 : WIRING DIAGRAM

IMPORTANT:

 THE COMBINED THERMOSTAT/CUT-OUT MUST BE PUSHED FULLY

                      HOME TO ENSURE CORRECT OPERATION OF THE CUT-OUT

COMBINED

THERMOSTAT

& CUT-OUT

THERMOSTAT

POCKET

ELEMENT

TERMINALS

CORRECT

INCORRECT

Содержание Hotflo 10

Страница 1: ...1 HOTFLO 10 15 Fitting Instructions and User Guide...

Страница 2: ...alling your Hotflo unvented water heater Particular attention should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissioning the operation of the heater sh...

Страница 3: ...15 litres Weight full 10 litre 16 5kg 15 litre 23 4kg Rated pressure 0 6 MPa 6 bar Minimum supply pressure 0 08 MPa 0 8 bar 15 Litre 10 Litre Dimension 613 457 A 656 500 B 516 360 C NOTE If fitting P...

Страница 4: ...be accommodated using an Expansion Vessel To ensure all expansion takes place in the vessel a Check Valve must also be fitted see Fig 03 page 5 Use Accessory Pack U5 code no 95 970 356 3 1 4 If the s...

Страница 5: ...IGURE 02 FOR INLET PRESSURES UP TO 0 41 MPa 4 1 BAR FIGURE 03 FOR INLET PRESSURES UP TO 0 41 MPa 4 1BAR WHERE EXPANSION IN MAIN SUPPLY IS NOT POSSIBLE FIGURE 04 FOR INLET PRESSURES ABOVE 0 41 MPa 4 1B...

Страница 6: ...age 3 and the Dimensions Table to determine a suitable position for the heater 3 2 3 NOTE Ensure that the wall can support the full weight of the unit see TECHNICAL SPECIFICATIONS and that there are n...

Страница 7: ...of the valves 3 5 DISCHARGE 3 5 1 The discharge outlet from the Pressure Expansion Relief Valve and the Temperature Pressure Relief Valve if fitted must be connected to a discharge pipe It is recommen...

Страница 8: ...ricity supply should be fused 13 Amp and be via a double pole isolating switch with a contact separation of at least 3mm in both poles Refer to Fig 06 below 3 6 2 The wires are colour coded as follows...

Страница 9: ...hed the indicator light will go out 5 0 EXPLANATION TO USER Following Installation and Commissioning of the water heater the operation should be fully explained to the user 5 1 HOT WATER 5 1 1 Indicat...

Страница 10: ...ing any work on the water heater Water contained in the water heater may be very hot To ensure the continued safe and efficient operation of the water heater it should be regularly maintained In hard...

Страница 11: ...th links to the earthing stud 6 3 4 Remove the element plate assembly by unscrewing the five securing screws tapped jacking points are provided Remove any loose scale from the container Carefully clea...

Страница 12: ...60 p s i This can reduce over time and eventually require re charging To do this 6 5 2 Turn off water supply to the unit open a hot tap to relieve system pressure 6 5 3 Remove dust cap from top of Exp...

Страница 13: ...lve Discharge of water from INSTALLATION POINTS page 4 1 Fit Pack U2 see IMPORTANT possible 1 Expansion in mains not intermittently Presure Relief Valve Discharge of water from 2 Fit Packs U1 and U2 4...

Страница 14: ...12 633 Indicator light 95 607 992 Element plate gasket 95 611 708 Pressure Expansion Relief Valve 95 607 986 Temperature Pressure Relief Valve 95 970 359 Check Valve 95 607 987 Expansion Vessel 95 607...

Страница 15: ...tions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner container with integral immersion heater is not guaranteed against excess...

Страница 16: ...Hexagon Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 020 8606 3567 Parts Centre Tel 0845 2709800 www partscentre co uk Newey Eyre Specialist Products Division Please contact your loc...

Отзывы: