7.0 FAULT FINDING

WARNING: Disconnect from all electrical supplies before beginning any work 

on the water heater. Water contained in the water heater may be very hot!

The  water  heater  should  give  trouble  free  operation,  however  should  a 

problem occur, the tables below should enable most faults to be identified 

with ease. 

Fault  Finding  should  be  carried  out  by  a  competent  person  and  any 

replacement parts used should be authorised Heatrae Sadia spare parts.

ACTION

POSSIBLE CAUSES

FAULT

1. Check electrical supply

1. Electrical supply fault

Water not heating

WiringDiagram, page 8)

replace thermostat/thermal cut-out (see

check thermostat operation. If necessary

2. Check cut-out, if operated reset and

2. Thermal cut-out tripped

necessary

3. Check thermostat operation, replace if

3. Thermostat fault

POINTS, page 4)

U2 (see IMPORTANT INSTALLATION

Fit Pressure Reducing Valve Pack U1 and

pressure

Excessive mains water

(continuously)

Pressure Relief Valve

Discharge of water from

INSTALLATION POINTS, page 4)

1. Fit Pack U2 (see IMPORTANT

possible

1. Expansion in mains not

(intermittently)

Presure Relief Valve

Discharge of water from

2. Fit Packs U1 and U2

4.1 bar (60 p.s.i.)

2. Mains pressure exceeds

3. Fit Pack U2 when using Pack U1

Pack U2

3. Pack U1 fitted without

4. Replace Pressure Relief Valve

4. Pressure Relief Valve Fault

(see Section 6.5)

Expansion Vessel pre-charge pressure

5. Check and, if necessary, re-charge

Expansion Vessel

5. Loss of pressure from

Replace thermostat and thermal cut-out

cut-out fault

Thermostat and thermal

Pressure Relief Valve

water/steam from

Relief Valve and or

Temperature/Pressure

Discharge of water from

in accordance with flow direction arrows

1. Check all valves are correctly installed

fitted

1. Inlet valves incorrectly

No water flow

2. Check mains water supply is on

turned on

2. Mains water supply not

fitted check the strainer is not blocked

3. Check for obstructions. If Pack U1 is

supply

3. Blockage in mains water

while.

milkiness will disappear after a short

oxygen bubbles when flowing. The

Water from a pressurised system releases

Oxygenated water

 "Milky" water

Содержание Hotflo 10

Страница 1: ...1 HOTFLO 10 15 Fitting Instructions and User Guide...

Страница 2: ...alling your Hotflo unvented water heater Particular attention should be paid to the section headed IMPORTANT INSTALLATION POINTS Following installation and commissioning the operation of the heater sh...

Страница 3: ...15 litres Weight full 10 litre 16 5kg 15 litre 23 4kg Rated pressure 0 6 MPa 6 bar Minimum supply pressure 0 08 MPa 0 8 bar 15 Litre 10 Litre Dimension 613 457 A 656 500 B 516 360 C NOTE If fitting P...

Страница 4: ...be accommodated using an Expansion Vessel To ensure all expansion takes place in the vessel a Check Valve must also be fitted see Fig 03 page 5 Use Accessory Pack U5 code no 95 970 356 3 1 4 If the s...

Страница 5: ...IGURE 02 FOR INLET PRESSURES UP TO 0 41 MPa 4 1 BAR FIGURE 03 FOR INLET PRESSURES UP TO 0 41 MPa 4 1BAR WHERE EXPANSION IN MAIN SUPPLY IS NOT POSSIBLE FIGURE 04 FOR INLET PRESSURES ABOVE 0 41 MPa 4 1B...

Страница 6: ...age 3 and the Dimensions Table to determine a suitable position for the heater 3 2 3 NOTE Ensure that the wall can support the full weight of the unit see TECHNICAL SPECIFICATIONS and that there are n...

Страница 7: ...of the valves 3 5 DISCHARGE 3 5 1 The discharge outlet from the Pressure Expansion Relief Valve and the Temperature Pressure Relief Valve if fitted must be connected to a discharge pipe It is recommen...

Страница 8: ...ricity supply should be fused 13 Amp and be via a double pole isolating switch with a contact separation of at least 3mm in both poles Refer to Fig 06 below 3 6 2 The wires are colour coded as follows...

Страница 9: ...hed the indicator light will go out 5 0 EXPLANATION TO USER Following Installation and Commissioning of the water heater the operation should be fully explained to the user 5 1 HOT WATER 5 1 1 Indicat...

Страница 10: ...ing any work on the water heater Water contained in the water heater may be very hot To ensure the continued safe and efficient operation of the water heater it should be regularly maintained In hard...

Страница 11: ...th links to the earthing stud 6 3 4 Remove the element plate assembly by unscrewing the five securing screws tapped jacking points are provided Remove any loose scale from the container Carefully clea...

Страница 12: ...60 p s i This can reduce over time and eventually require re charging To do this 6 5 2 Turn off water supply to the unit open a hot tap to relieve system pressure 6 5 3 Remove dust cap from top of Exp...

Страница 13: ...lve Discharge of water from INSTALLATION POINTS page 4 1 Fit Pack U2 see IMPORTANT possible 1 Expansion in mains not intermittently Presure Relief Valve Discharge of water from 2 Fit Packs U1 and U2 4...

Страница 14: ...12 633 Indicator light 95 607 992 Element plate gasket 95 611 708 Pressure Expansion Relief Valve 95 607 986 Temperature Pressure Relief Valve 95 970 359 Check Valve 95 607 987 Expansion Vessel 95 607...

Страница 15: ...tions 4 The unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner container with integral immersion heater is not guaranteed against excess...

Страница 16: ...Hexagon Business Centre Springfield Road Hayes Middlesex UB40 0TY Tel 020 8606 3567 Parts Centre Tel 0845 2709800 www partscentre co uk Newey Eyre Specialist Products Division Please contact your loc...

Отзывы: