![Heatrae Sadia HANDY NO-TOUCH Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/heatrae-sadia/handy-no-touch/handy-no-touch_fitting-instructions-and-user-manual_2117659005.webp)
5
ELECTRICAL
2.20 Before fitting the appliance, ensure that the consumer unit and any
switches are suitable for the additional load. If in doubt, contact your
electricity supplier or a qualified electrician.
2.21 The installation must comply with BS 7671 ‘Requirements for
electrical installations’ (IEE Wiring Regulations).
CAUTION
2.22 This appliance must be earthed.
2.23 Fuses do not give personal protection against electric shock.
To
enhance electrical safety a 30mA residual current device (RCD)
should be installed in all electric handwash circuits.
This may be
part of the consumer unit, or a separate unit.
2.24 Ensure that all terminal block connections are sufficiently tight.
2.25 Switch off appliance immediately and isolate if water ceases to flow
during use.
2.26 Other electrical equipment e.g. extractor fans, must not be connected
to the handwash or its supply circuit.
3.0 TECHNICAL SPECIFICATIONS
3.1 CONNECTIONS
Inlet connection -15mm ext. diameter (copper or push fit stem elbow)
Water entry point - bottom and rear
Cable entry point - bottom and rear
3.2 ELECTRICAL
Model numbers
3.1kW - Handwash - 95 020 115
Nominal Power Rating
Model
240V
230V
Minimum
cable size
3.1kW
3.1kW
12.9 amp
2.9kW
12.4 amp
1.5mm
2