9.0 FAULT FINDING
9.1 In the unlikely event of a problem, consult the trouble-shooting chart
below.
9.2 If you are unable to remedy the problem, CONTACT YOUR
INSTALLER in the first instance.
IMPORTANT
9.3 Do not attempt any electrical or plumbing work unless you are
competent to do so.
9.4 If you still cannot solve the problem, please contact Heatrae Sadia.
INSPECTION
9.5 It is advisable that, in the interests of safety, the handwash and its
electrical installation is checked by a competent electrician, at least
every two years.
SYMPTOM
POSSIBLE CAUSE
REMEDY
A. Water supply turned off
Turn on water supply
B. Unit frozen
Turn OFF ELECTRICITY at isolating switch
and contact installer. DO NOT USE THE
HANDWASH.
C. Spout blocked
Clean sprayplate - see 10.2
D. Filter blocked
Clean filter
E. Electrical power to
appliance off
A. Torx adjusting screw at
Turn torx screw clockwise until temperature
wrong setting
is comfortable
B. Water flow too high
Turn torx screw clockwise until temperature
is comfortable
C. Poor flow
Check inlet pressure
A. Torx adjusting screw at
Turn torx screw fully anticlockwise to increase
wrong setting
flow and lower temperature
B. Spout partially blocked
Clean sprayplate - see 10.2
C. Isolating valve not fully
Open isolating valve
open
D. Filter blocked
Clean filter
A. Spout blocked
Clean sprayplate - see 10.2
Push plastic plunger up and back in place.
pressure relief
B. Spout not blocked
Call a service engineer, as there may be a
problem with internal parts.
Ensure that the electricity supply to the
appliance is switched on
with valve open
device
1. No water flows
2. Water too cold
3. Water too hot
4. Water runs from
Fault Finding Table