67
Rev. 05/2020
CHAPTER 23
MAINTENANCE CHECKLIST
Season Start-Up
To begin season start-up of your Heatmor
TM
Outdoor Furnace, assuming you followed the
procedures outlined in the “End of Season Maintenance Checklist,” follow the instructions
below:
1) Remove cap from chimney.
2) Build fire in firebox and bring your furnace up to temperature. Refer to “
Lighting
the Heatmor
TM
for the First Time”
3) Once your furnace is up to temperature, you can start all pumps.
4) Your start-up is complete.
CAUTION:
It is recommended to start your pumps AFTER
you bring your furnace up to temperature. This helps to see if
your system is air locked and ensures your HTF is
circulating
correctly.
End of Season
To begin End of Season Shutdown of your Heatmor™ Outdoor Furnace, follow the
instructions below:
1) Turn off pump(s).
2) Clean Flue Refer to “Flue”
A) Remove the one-half inch nuts holding the flue cover and remove the cover.
B) Using the flue scraper provided with the HEATMOR™ furnace, push the dust
to the front of the flue and let it fall down into the firebox. Remove this dust as
you would ashes. If a lot of dust is dropped down, be certain that the air slot of
the front air box is not covered.
C) Re-attach the flue cover plate, making sure to tighten the nuts to make an
airtight seal.
3) Clean ashes out of Firebox. Refer to “Ashes”
A) Thoroughly pull ashes from sides and corners of Firebox. Rake ashes in Firebox
down into the grates.
4) Auger ashes out of Ash Pan. Refer to “Ashes”
5)
Place cap on Chimney. There is no specific product sold for this use, but a five gallon
bucket or something similar will cover the chimney keeping unwanted moisture and
visitors away.