Wiring Centre

4

5

Model: 

UH8

Zones 1…8 

Zones outputs are clearly marked
L = live out to actuator or valve 
N = neutral to actuator or valve
There are two connections live (L) and neutral (N), both terminals 
marked L are the same and both terminals marked N are the same.
Each zone output corresponds to the thermostat wired in at the  
top of the pcb. 

UFH Pump 

Used for an underfloor heating manifold pump.
Connections are clearly marked
L = Live 
E = Earth 
N = Neutral
When an under-floor heating zone sends a call for heat to the UH8, the 
live & neutral output will supply 230v to the manifold pump.
It is recommended that this is fed through a high limit switch placed 
on the heating manifold, to protect against mechanical failure of the 
manifolds temperature control.

UFH Valve 

Used for an underfloor heating manifold valve.
Connections are clearly marked;
Gr = Grey 
Or = Orange 
L = Live 
E = Earth 
N = Neutral
When an under-floor heating zone sends a call for heat to the UH8,  
the live & neutral output will supply 230v to the manifold valve.
The auxiliary wires of the valve, usually grey & orange, are wired to the 
Gr & Or terminals.

Fuses 

Fuse 1.

 5amp, 20mm anti-surge fuse, this fuse supplies  

power to all 230v outputs from the board it protects the zone,  
pump/valve outputs.

Connections 
Mains Supply

Power supply into the UH4 which should be fused at 5 amps these 
connections are marked 
L = live or phase 230v AC 50/60Hz 
N = Neutral 
E = Earth 

Heat Enable

This is the main call for heat for the system, there are 3 connections;
LS = Live Supply 
E = Earth 
LR = Live Return
Electrically this is a volt free switch, whatever supply is placed on the 
LS connection, is fed to the LR connection when there is a call for heat.

UH8 Wiring

Ratings

Number of Heating Zones

Neon Indication

DIN Rail Mounting

Supply

230v AC 50Hz 1 Phase 

Relay Load Max

3 Amp Resistive 

Total Load Max

5 Amp Resistive 

IP Protection

IP20 

Installed Dimensions (L,H,D)

384 x 148 x 60mm 

Weight

800g 

Содержание UH8

Страница 1: ...Model UH8...

Страница 2: ...ut WILL NOT enable the underfloor heating pump valve output If the switch is set to UFH When Zone 8 calls for heat this will act as an underfloor heating zone by enabling the actuator boiler and pump...

Страница 3: ...ive E Earth N Neutral When an under floor heating zone sends a call for heat to the UH8 the live neutral output will supply 230v to the manifold valve The auxiliary wires of the valve usually grey ora...

Страница 4: ...PE UH8 DS SB TM4 4 Under floor 1 Radiator zone This equipment should be installed by an appropriately qualified registered electrician Fully read the instructions for proper wiring before applying pow...

Страница 5: ...mproper wiring or installation 5A FUSE PLEASE ADD LINK TO GR AND OR IF VALVE IS NOT FITTED ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V UFM UNDER F...

Страница 6: ...LS AND LR IS VOLT FREE EARTH END SWITCH AND BOILER ENABLE UFM UNDER FLOOR MANIFOLD LIVE SWITCHLIVE NEUTRAL N N N N N 1 A 1 A NC A1 T R RT2 RT2 RT RT1 RT1 A2 A2 COM NO A2 A2 L L L L L NEOSTAT TOUCH SL...

Страница 7: ...ring Centre 12 13 Model UH8 System Configuration Notes PLEASE COMPLETE DURING INSTALLATION UH8Title In Use ZoneType ZoneTitle Under Floor Radiator Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone...

Страница 8: ...Wiring Centre 14 15 Model UH8 Notes Notes...

Страница 9: ...ion Products Commonly used with the UH8 wiring centre PDF FAQ VIDEO Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmis...

Отзывы: