UH8 – Installation Manual

Description

The UH8 is an 8 Zone wiring centre for use with Heatmiser  
230v thermostats.
The UH8 can be used to control any actuator or valve which requires a 
230v AC signal. At the same time the UH8 offers the ability to operate a 
boiler or other heat source through a volt free output.
Additional outputs designed for use with underfloor heating systems 
are also included as standard. These are the pump and valve outputs 
which would normally operate a manifold pump or a manifold valve.
Zone 8 can be used as an isolated radiator zone by using the  
UFH/RAD switch.
If the switch is set to 

RAD

;

When zone 8 calls for heat this will provide an output to a radiator 
zone valve and the boiler, but 

WILL NOT

 enable the underfloor 

heating pump/valve output.
If the switch is set to 

UFH

;

When Zone 8 calls for heat, this will act as an underfloor heating zone, 
by enabling the actuator, boiler and pump/valve outputs.
Any output which is not needed can be ignored.

Installation

The UH8 can be mounted directly to a wall using four screws or 
alternatively, the unit can be DIN rail mounted.

When DIN Rail mounting, you first need to insert the two clips 
provided on the back of the UH8, as shown in the image;

 

• 

 On the back of the UH8, position the clip in the middle  
and slide down.

 

• 

 Points A and B locate in the corresponding holes and  
lock into place.

 

• 

 Locate the UH8 onto the DIN rail from the top.

 

• 

 Pull the clip down and push the bottom of the UH8 onto  
the DIN rail.

 

• 

 Releasing the clip will lock the UH8 in place on the DIN rail.

To remove the UH8, pull both clips down and remove from the DIN rail.

B

A

Insert clip here.

Then Slide down to lock in place.

Содержание UH8

Страница 1: ...Model UH8...

Страница 2: ...ut WILL NOT enable the underfloor heating pump valve output If the switch is set to UFH When Zone 8 calls for heat this will act as an underfloor heating zone by enabling the actuator boiler and pump...

Страница 3: ...ive E Earth N Neutral When an under floor heating zone sends a call for heat to the UH8 the live neutral output will supply 230v to the manifold valve The auxiliary wires of the valve usually grey ora...

Страница 4: ...PE UH8 DS SB TM4 4 Under floor 1 Radiator zone This equipment should be installed by an appropriately qualified registered electrician Fully read the instructions for proper wiring before applying pow...

Страница 5: ...mproper wiring or installation 5A FUSE PLEASE ADD LINK TO GR AND OR IF VALVE IS NOT FITTED ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V UFM UNDER F...

Страница 6: ...LS AND LR IS VOLT FREE EARTH END SWITCH AND BOILER ENABLE UFM UNDER FLOOR MANIFOLD LIVE SWITCHLIVE NEUTRAL N N N N N 1 A 1 A NC A1 T R RT2 RT2 RT RT1 RT1 A2 A2 COM NO A2 A2 L L L L L NEOSTAT TOUCH SL...

Страница 7: ...ring Centre 12 13 Model UH8 System Configuration Notes PLEASE COMPLETE DURING INSTALLATION UH8Title In Use ZoneType ZoneTitle Under Floor Radiator Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone...

Страница 8: ...Wiring Centre 14 15 Model UH8 Notes Notes...

Страница 9: ...ion Products Commonly used with the UH8 wiring centre PDF FAQ VIDEO Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmis...

Отзывы: